AT404 ETC2 [List of Unclassifed Manufacturers], AT404 Datasheet

no-image

AT404

Manufacturer Part Number
AT404
Description
EZYTRIGGER
Manufacturer
ETC2 [List of Unclassifed Manufacturers]
Datasheet
AT404 E
April 2002
The AT404 EasyTrigger in combination with a fibre optic
cable replaces pulse transformers including all associated
circuitry in phase controlled thyristor equipment. It is
intended for applications where high insulation voltages or
long transmitting distances are important. Because of the
small control current, the unit serves as an ideal link
between the control intelligence and the thyristor. Each unit
triggers a single thyristor and is intended for 115 -
690Vrms supplies.
The operation of the AT404 is based on a controlled
current source connected between anode and gate of the
thyristor to be triggered. The large gate current is initiated
by the output current from a fibre optic receiver diode. With
a suitable transmitter, small and large thyristors can be
triggered directly from standard logic circuits without the
need of a gate drive power supply. The receiver diode is
not part of the unit.
Among the many possible applications, it is specifically
useful in electrostatic precipitators.
ABSOLUTE MAXIMUM RATINGS
TECHNICAL DATA
APPLICATION INFORMATION
The sensitivity of the fibre optic system is important if it is desirable to drive the AT404 directly from the
control logic. For a receiver diode output above 30µA the turn-on delay is approximately inversely
proportional to the current and therefore pulse shaping can reduce the turn-on delay down to a
Peak voltage - positive and negative
Nominal mains voltage
Continuous DC voltage
Turn-on delay for gate current = 1A
Transient immunity
Ambient temperature
External gate cathode short circuit during operation can be destructive
200mA Gate current threshold
1.2A gate current threshold
Gate current rise time at anode
voltage of
Peak gate current (typical)
Anode - cathode current at Vp
Maximum off state gate current
Minimum output current of receiver diode
Minimum voltage rating of receiver diode
Turn-on delay with receiver current = 30uA
Parameter
Parameter
ZY
T
at 25°C
RIGGER
1200V
100V
200V
400V
800V
Data subject to change without notice
Symbol
Symbol
(di/dt)g
Vgtm
Vcm
Vgtl
Icm
(dv/dt)d
tdi
Ip
In
Io
Vm
tdg
Vp
V=
Ta
AT404-22
AT404-22
1.2
2.5
1.3
5.1
16
36
15
30
35
2
3
4
2
2200
2000
690
690
5
-25 to +85
AT404
AT404-24
AT404-24
1.2
2.5
1.3
5.8
16
36
15
30
35
2
3
4
2
2400
2000
690
690
5
Actual Size
Page 1 of 2
Vrms
V/ s
A/ s
Unit
Unit
Vdc
mA
ºC
V
V
V
A
V
A
A
s
s

Related parts for AT404

AT404 Summary of contents

Page 1

... Turn-on delay with receiver current = 30uA APPLICATION INFORMATION The sensitivity of the fibre optic system is important desirable to drive the AT404 directly from the control logic. For a receiver diode output above 30µA the turn-on delay is approximately inversely proportional to the current and therefore pulse shaping can reduce the turn-on delay down to a ...

Page 2

... T ZY RIGGER minimum of about 5µS. The printed circuit board tracks from the fibre optic receiver to the AT404 EasyTrigger need short as possible. Furthermore the (+) track should preferably surround the (-) track to minimize capacitive interference from fast rising voltages in the vicinity. Since the gate current is derived from the anode of the thyristor no gate drive power supply is required ...

Related keywords