The first data byte goes into the internal register of the
MPR081 selected by the command byte
condition is detected, these bytes are generally stored in
subsequent MPR081 internal registers because the
command byte address generally auto-increments
MESSAGE FORMAT FOR READING THE MPR081
command byte as address pointer, the same way the stored
command byte is used as address pointer for a write. The
OPERATION WITH MULTIPLE MASTERS
multiple masters, a master reading the MPR081 should use
repeated start(s) between the write(s) which sets the
MPR081's address pointer, and the read(s) that take the data
from the location(s). This is because it is possible for master
#2 to take over the bus after master #1 has set up the
MPR081's address pointer, but before master #1 has read
the data. If master #2 subsequently re-sets the master of the
REGISTER ORGANIZATION
monitored though a small array of internal registers which are
accessed through the I
INITIAL POWER-UP
will go high. The registers are reset to the values shown in
Table
STANDBY MODE
automatically enters standby mode. If any of the features are
Any bytes received after the command byte are data bytes.
If multiple data bytes are transmitted before a STOP
The MPR081 is read using the MPR081's internally stored
If the MPR081 is operated on a 2-wire interface with
The MPR081 is a peripheral that is controlled and
On power-up, the interrupt output IRQ is reset, and IRQ
When the serial interface is idle, the MPR081
9.
2
C bus.
Figure 10. Command and Single Data Byte Received
CONTROLLING AND READING THE MPR081
(Figure
Figure 11. ‘n’ Data Bytes Received
10).
(Table
8).
pointer generally auto-increments after each data byte is read
using the same rules as for a write
initiated by first configuring the MPR081's command byte by
performing a write
consecutive bytes from the MPR081, with the first data byte
being read from the register addressed by the initialized
command byte. When performing read-after-write
verification, remember to re-set the command byte's address
because the stored command byte address will generally
have been auto-incremented after the write
MPR08's address pointer, then master #1's read may be from
an unexpected location.
DEVICE RESET
low, RST clears any transaction to or from the MPR081 on
the serial interface and configures the internal registers to the
same state as a power-up reset
waits for a START condition on the serial interface.
used, the operating current rises because the internal timing
oscillator is running and toggling counters.
The reset input RST is an active-low input. When taken
Pad/Key Input Sampling with Autorepeat
Figure 12. Master Tick Counter and
(Figure
9). The master can now read 'n'
(Table
(Table
9). The MPR081 then
11). Thus, a read is
(Table
8).
MPR081
9