Page 1
... Performance Guaranteed ° ° over - +125 C • Input • Programmable Sense Voltage • Hysteresis • HCPL-3700 Operating Compatibility • Logic Compatible Output • 1500 Vdc Withstand Test Voltage • Thresholds Guaranteed over Temperature • Thresholds Independent of LED Characteristics The connection of a 0.1 µ ...
Page 2
... These units combine several unique functions in a single package, providing the user with an ideal component for computer HCPL-5760 HCPL-5761 HCPL-576K Gold Option #200 Option #100 Option #300 Option #600 5962- 8947701PX 8947701PC ...
Page 3
Absolute Maximum Ratings Storage Temperature Range ....................................... -65°C to +150°C Operating Temperature .................................................. -55°C to 125°C Lead Solder Temperature ............................................. 260°C for 10 s Average Input Current, I ........................................................ Surge Input Current, I ................................................... 140 mA IN,SG ...
Page 4
Hermetic Optocoupler Options Option 100 Surface mountable hermetic optocoupler with leads trimmed for butt joint assembly. This option is available on commercial and hi-rel product. 0.51 (0.020) MIN. 2.29 (0.090) 2.79 (0.110) 200 Lead finish is solder dipped rather than ...
Page 5
Electrical Characteristics Parameter Symbol I TH+ Input Threshold Current I TH- V TH+ dc (Pins TH- Input Threshold Voltage V TH+ ac (Pins TH- V IHC1 Input Clamp Voltage V IHC2 V IHC3 Input ...
Page 6
Electrical Characteristics Parameter Symbol Propagation Delay Time to Logic Low t PHL Output Level Propagation Delay Time to Logic High t PLH Output Level Logic High Common Mode Transient | Immunity Logic Low Common Mode Transient |CM | ...
Page 7
Typical Characteristics All typical values are at T Parameter Symbol Hysteresis Input Clamp Voltage Bridge Diode Forward Voltage Input-Output Resistance Input-Output Capacitance Input Capacitance Output Rise Time (10-90%) Output Fall Time (90-10%) Notes: 1. Maximum operating frequency is defined when ...
Page 8
... Figure 5. Typical High Level Supply Current, I Temperature. HCPL-5760/1/K Figure 7. Switching Test Circuit. vs Figure 4. Typical Input Current Voltage vs. Temperature. OL vs. Figure 6. Typical Propagation Delay vs. Temperature. CCH Figure 8. Test Circuit for Common Mode Transient Immunity and Typical Waveforms and Low Level Output IN HCPL-5760/1/K ...
Page 9
... Equations (2) and (3). R can provide over-current x transient protection by limiting input current during a transient condition. For monitoring contacts with a relay or switch, the HCPL-5760/1/K, or 5962-89477 combination with R x and R can be used to allow a p specific current to be conducted through the contacts for cleaning purposes (wetting current). ...
Page 10
... Test Program Agilent Technologies’ Hi-Rel Optocouplers are in compliance with MIL-PRF-38534 Class H and K. Class H and Class K devices are also in compliance with DSCC drawing 5962-89477. Testing consists of 100% screen- ing and quality conformance inspection to MIL-PRF-38534. HCPL-5760/1/K Figure 11. External Threshold Voltage Level Selection. 10 ...
Page 11
Data subject to change. Copyright © 2001 Agilent Technologies August 23, 2001 Obsoletes 5968-9404E (11/00) 5988-3093EN ...