OPA623AP BURR-BROWN [Burr-Brown Corporation], OPA623AP Datasheet - Page 14

no-image

OPA623AP

Manufacturer Part Number
OPA623AP
Description
Wide Bandwidth, Current-Feedback OPERATIONAL AMPLIFIER
Manufacturer
BURR-BROWN [Burr-Brown Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
OPA623AP
Manufacturer:
BB
Quantity:
5 510
FIGURE 14. Mask of a Pulse Corresponding to a Binary 1 per CCITT Recommendation G.703.
zero level
Nominal
(2)
–0.05
–0.40
–0.45
–0.50
–0.55
–0.60
NOTE: (1) The maximum “steady state” amplitude should not exceed the 0.55V limit. Overshoots and other transients are permitted to
fall into the dotted area, bounded by the amplitude levels 0.55V and 0.6V, provided that they do not exceed the steady state level by
more than 0.05V. The possibility of relaxing the amount by which the overshoot may exceed the steady state level is under study.
(2) For all measurements using these masks, the signal should be AC coupled, using a capacitor of not less than 0.01µF, to the input of
the oscilloscope used for measurements.
The nominal zero level for both masks should be aligned with the oscilloscope trace with no input signal. With the signal then applied,
the vertical position of the trace can be adjusted with the objective of meeting the limits of the masks. Any such adjustment should be
the same for both masks and should not exceed 0.05V. This may be checked by removing the input signal again and verifying that the
trace lies within 0.05V of the nominal zero level of masks.
(3) Each pulse in a coded pulse sequence should meet the limits of the relevant mask, irrespective of the state of the preceding and
succeeding pulses. For actual verification, if a 139264kHz timing signal associated with the source of the interface signal is available, its
use as a timing reference for an oscilloscope is preferred. Otherwise, compliance with the relevant mask may be tested by means of all-
0s and all-1s signals, respectively. (In practice, the signal may contain frame alignment bits per Rec. G.751.)
(4) For the purpose of these masks, the rise time and decay time should be measured between –0.4V and 0.4V, and should not exceed
2ns.
(5) The inverse pulse will have the same characteristics. Note that the timing tolerance at the zero level of the negative and positive
transitions are ±0.1ns and ±0.5n, respectively.
0.60
0.55
0.50
0.45
0.40
0.05
V
®
= Note 1.
OPA623
0.1ns
1ns
0.1ns
Negative
transition
1ns
1.795ns
3.59ns
1.35ns
14
T = 7.18ns
1.35ns
3.59ns
Positive transition
Nominal
Pulse
1.795ns
1ns
0.5ns
0.5ns
1ns