10.4.4 IBV Monitoring
The DPM continuously monitors the intermediate bus voltage via the IBVS input and the built-in 10-bit ADC. The
digital representation of the bus voltage is stored in RAM and reported in the IBS Monitoring window shown in
Figure 11.
In addition, the DPM continuously compares the value of IBV to the Undervoltage and Overvoltage thresholds
programmed in the GUI Intermediate Bus Configuration Window shown in Figure 12.
Figure 12. Intermediate Bus Configuration Window
The thresholds have a symmetric, fixed size hysteresis as shown in Figure 13
Figure 13: Undervoltage (IBL) and Overvoltage (IBH) Protections Hysteresis
When the IBV decreases below the IBL threshold minus the hysteresis, the DPM will pull OK lines low turning off
all POL converters.
The POL converters will execute regular turn-off ramping their output voltages down
according to the turn-off delay and falling slew rate settings. In addition, the DPM will clear all bits in the POL
Programming Status registers and save the content of the Run Time Counter into the non-volatile memory. The
IBV Low bit in the IBS Monitoring Window will change to red. When the IBV recovers above the IBL threshold plus
REV. 3.3 NOV 26, 2007