LM92_05 NSC [National Semiconductor], LM92_05 Datasheet - Page 7

no-image

LM92_05

Manufacturer Part Number
LM92_05
Description
Manufacturer
NSC [National Semiconductor]
Datasheet
Note 13: This specification is provided only to indicate how often temperature data is updated. The LM92 can be read at any time without regard to conversion state
(and will yield last conversion result). If a conversion is in process it will be interrupted and restarted after the end of the read.
Note 14: For best accuracy, minimize output loading. 10k pull-ups resistors should be sufficient. Higher sink currents can affect sensor accuracy with internal
heating. This can cause an error of 0.64 ˚C at full rated sink current and saturation voltage based on junction-to-ambient thermal resistance.
Note 15: Hysteresis value adds to the T
subtracts from the T
discussion of the function of hysteresis refer to Section 1.1, TEMPERATURE COMPARISON, and Figure 3.
Note 16: Default values set at power up.
Note 17: Holding the SDA and/or SCL lines Low for a time interval greater than t
bus communication (SDA and SCL set High).
HIGH
and T_CRIT setpoints (e.g.: if T
FIGURE 2. Temperature-to-Digital Transfer Function (Non-linear scale for clarity)
LOW
setpoint value (e.g.: if T
HIGH
setpoint = 64 ˚C, and hysteresis = 2 ˚C, then actual hysteresis point is 64−2 = 62 ˚C). For a detailed
LOW
setpoint = 10 ˚C, and hysteresis = 2 ˚C, then actual hysteresis point is 10+2 = 12 ˚C); and
TIMEOUT
7
will cause the LM92 to reset SCL and SDA to the IDLE state of the serial
10105105
www.national.com

Related parts for LM92_05