TMP30-05 TRUMPOWER [Tumbler Technologies + TRUMPower], TMP30-05 Datasheet

no-image

TMP30-05

Manufacturer Part Number
TMP30-05
Description
30 WATT MEDICAL POWER ADAPTERS
Manufacturer
TRUMPOWER [Tumbler Technologies + TRUMPower]
Datasheet
TRUMPower
D E SCR IPTION
The TMP30 series of AC/DC switching power
adapters are capable of delivering 25 to 30 watt
output power. They are enclosed in a 94V-1
rated polyphenylene-oxide case with an IEC320
inlet to mate with interchangeable cord for
world-wide use. All models meet CISPR 11 and
FCC class B emission limits, and are designed
for medical applications.
F EATU R E S
‧ 1 0 s ta n d a r d d e s k t o p m o d e l s .
‧ O p t i o n a l o u t p u t c o n n e c t o r s
‧ O p t i o n a l o n / o f f s w i t c h
‧ 1 0 0 % b u r n - i n a t f u l l r a t e d l o a d
‧ 9 0 VA C t o 2 6 4 VA C u n i v e r s a l i n p u t
‧ I n p u t s u r g e c u r r e n t p r o t e c t i o n
‧ O v e r v o l ta g e p r o t e c t i o n
‧ O v e r c u r r e n t p r o t e c t i o n
‧ S h o r t - c i r c u i t p r o t e c t i o n w i t h a u t o - r e c o v e r y
INPUT SPECIFICATIONS
OUTPUT SPECIFICATIONS
Output voltage/current:
Output power range:
Ripple and noise:
Overvoltage protection: Set at 112-132% of the higher
Overcurrent protection: The output is protected to
Temperature coefficient: All outputs ±0.04%/ºC
Transient response:
E N V IR O N M ENTA L SP E C IF ICATI O N S
O p e r a t i n g t e m p e r a t u r e:
S t o r a g e t e m p e r a t u r e :
R e l a t i v e h u m i d i t y :
Derating:
I n p u t v o l ta g e :
I n p u t f r e q u e n c y :
I n p u t c u r r e n t :
L e a k a g e c u r r e n t :
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com
8 5 t o 2 6 4 VA C
4 7 t o 6 3 H z
0 . 8 0 A ( r m s ) f o r 11 5 VA C
0 . 5 0 A ( r m s ) f o r 2 3 0 VA C
9 0 µ A m a x . @ 11 5 VA C , 6 0 H z
1 5 0 µ A m a x . @ 2 3 0 VA C , 5 0 H z
See rating chart
30 watts maximum
1% peak to peak maximum
extreme of its nominal output
voltage
short circuit conditions
maximum
Maximum excursion of 4% or
better on all models,
recovering to 1% of final
value within 500µs after a
25% step load change
0 º C t o + 7 0 º C
- 4 0 º C t o + 8 5 º C
5 % t o 9 5 % n o n - c o n d e n s i n g
Derate from 100% at +50ºC
linearly to 50% at +70ºC
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Tumbler Technologies + TRUMPower
30 WATT MEDICAL POWER ADAPTERS
TMP30 SERIES
Saf et y Sta n da rd A ppr o va ls:
GENERAL SPECIFICATIONS
Switching frequency : 70KHz ±5KHz
Efficiency:
Hold-up time:
Line regulation:
Inrush current:
Withstand voltage:
MTBF:
EMC Performance (EN60601-1-2: 2001)
EN55011:
FCC:
VCCI:
EN61000-3-2:
EN61000-3-3:
EN61000-4-2:
EN61000-4-3:
EN61000-4-4:
EN61000-4-5:
EN61000-4-6:
EN61000-4-8:
EN61000-4-11:
UL 2601-1,
CSA C22.2 No. 601.1
Class B conducted, class B radiated
Class B conducted, class B radiated
Class B conducted, class B radiated
Harmonic distortion, class A and D
Line flicker
ESD, ±8KV air and ±6KV contact
Radiated immunity, 3V/m for 80~2500MHz
Fast transient/burst, ±2KV
Surge, ±1KV diff, ±2KV com.
Conducted immunity, 3Vrms
Magnetic field immunity, 3A/m
Voltage dips, 30% reduction for 500ms,
60% reduction for 100ms and >95%
reduction for 10ms
TÜV EN60601-1
70% minimum on all models with
output voltage ≥7V or 65% minimum
on the others
20ms minimum at 115VAC
±0.5% maximum at full load
15A @ 115VAC, or 30A @ 230VAC, at
25ºC and cold start
4000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
400,000 hours minimum at full load at
25ºC ambient, calculated per
MIL-HDBK-217F
(MDD)