OVER‐VOLTAGE PROTECTION (OVP) 
Over‐voltage protection in IR3894 is achieved by 
comparing sense pin voltage Vsns to a pre‐set threshold.  
In non‐tracking mode, OVP threshold is set at 1.2*Vref; in 
tracking mode, it is at 1.2*Vp. When Vsns exceeds the over 
voltage threshold, an over voltage trip signal asserts after 
2us (typical.) delay. Then the high side drive signal HDrv is 
turned off immediately, PGood flags low. The low side 
drive signal is kept on until the Vsns voltage drops below 
the threshold. After that, HDrv is latched off until a reset 
performed by cycling either Vcc or Enable. 
Vsns voltage is set by the voltage divider connected to the 
output and it can be programmed externally. Figure 18 
shows the timing diagram for OVP in non‐tracking mode 
Figure 18: Timing Diagram for OVP in non‐tracking mode 
Figure 17: Vp Sequence and Vref Margin 
24
AUGUST 08, 2012 | DATA SHEET |    Rev 3.1
Single‐Input Voltage, Synchronous Buck Regulator  
 
- 24 -`
 
12A Highly Integrated SupIRBuck  
SOFT‐STOP (S_CTRL) 
Soft‐stop function can make output voltage discharge 
gradually. To enable this function, S_Ctrl is kept low first 
when EN goes high. Then S_Ctrl is pulled high to cross the 
logic level threshold (typical. 2V), the internal soft‐start 
ramp is initiated. So Vo follows Intl_SS to ramp up until it 
reaches its steady state. In soft‐stop process, S_Ctrl needs 
to be pulled low before EN goes low. After S_Ctrl goes 
below its threshold, a decreasing ramp is generated at 
Intl_SS with the same slope as in soft‐start ramp. Vo 
follows this ramp to discharge softly until shutdown 
completely. Figure 19 shows the timing diagram of S_Ctrl 
controlled soft‐start and soft‐stop. 
If the falling edge of Enable signal asserts before S_Ctrl 
falling edge, the converter is still turned off by Enable. 
Both gate drivers are turned off immediately and Vo 
discharges to zero. Figure 20 shows the timing diagram  
of Enable controlled soft‐start and soft‐stop. Soft stop 
feature also ensures that Vout discharges and also 
regulates the current precisely to zero with no undershoot. 
Enable
S_Ctrl
Enable
S_Ctrl
Vout
Vout
_SS
Intl
_SS
Intl
0
0
0
Figure 20: Timing Diagram for Enable controlled  
0
Figure 19: Timing Diagram for S_Ctrl controlled  
0
0
0
0
0.15V
0.65V
0.65V
0.15V
1.2V
Soft Start/Shutdown 
Soft Start/Soft Stop 
IR3894 
1.0V
PD‐97745
0.65V
0.15V
 
 