1.Contact resistance
2.Insulation resistance
3.Withstanding voltage
4.Vibration
5.Shock
6.Humidity
7.Temperature cycle
Connector Body
The test method conforms to JIS.
The temperature resistance cycle, humidity resistance, and shock resistance tests are verification tests of part deterioration and
looseness, not tests to be conducted at time of switching or when conducting.
Outer conductor
Inner conductor
Female contact
Product Specifications
Materials
Ratings
Insulator
RF Coaxial Switches (DC to 15 GHz)
HCS2 Series
Case
Part
Item
Frequency range
Characteristic impedance
Maximum Input Power
Beryllium copper
Beryllium copper
Stainless steel
Aluminum
Aluminum
Material
PTFE
Voltage drop of 4 mV max.
5000 M
No flashover or insulation breakdown
No electrical discontinuity of 1 µs or more
No damage, cracks, or parts dislocation
Insulation resistance: 1000 M
No damage, cracks, or parts dislocation
No damage, cracks, or parts dislocation
ohms
Conductive alumite
Black alumite
Gold plating
Gold plating
Passivated
Min.
Finish
Standard
------
DC to 15 GHz
50 ohms
15 W
ohms
min.
q
w
e
1.High Performance and High Reliability
2.SMA Connections
3.Environmentally Rugged
Series Name: HCS
Series No: 2
Type of Connector
Ordering Information
1: SMA
(Hirose Electric HRM Series)
Features
These switches are of the SPDT fail-safe type and
have been designed for wide frequency bandwidth,
contact voltage strength, power saving, and vibration
resistance.
SMA type coupling (Hirose Electric HRM Series) has
been used.
A wide variety of tests including temperature and
humidity cycles, high temperature power, low
temperature power, humidity,vibration, and shock have
been conducted and good results were obtained for all.
Operating temperature range
Operating relative humidity
HCS 2 - 1 1 0 - F
1 A DC
500 V DC
100 V AC/one minute
Frequency of 10 to 55 Hz, overall amplitude of 1.52 mm for 2 hours in ech of 3 directions,
Frequency of 10 to 500 Hz, acceleration of 49 m/s2 for 3 hours in each of 3 directions
Acceleration of 490 m/s
in each of the 3 axis
240 hours at temperature of 40
Temperature: -30
Time: 30 5 max. 30 5 max. (Minutes)
5 cycles
q
w
e r t
ç
+5
r
t
y
2
, sine half-wave waveform, 6 cycles
ç
Conditions
Switching Voltage
Presence of Auxiliary Contacts
Operation Method
1: 12V
2: 20V
3: 26V
0: No
1: Yes
F: Fail-safe type
to +35
ç
y
and humidity of 95%
ç
+65
0
(No freezing)
ç
90
4
5
:
:
ç
to
%
17V
10V
+
Max.
+5
50
ç
ç
to +35
ç
139