LMP91000SD NSC [National Semiconductor], LMP91000SD Datasheet

no-image

LMP91000SD

Manufacturer Part Number
LMP91000SD
Description
Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications
Manufacturer
NSC [National Semiconductor]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LMP91000SD/NOPB
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
LMP91000SD/NOPB
0
Part Number:
LMP91000SDE
Manufacturer:
TI
Quantity:
1
Part Number:
LMP91000SDE/NOPB
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
LMP91000SDE/NOPB
0
Part Number:
LMP91000SDX/NOPB
0
© 2011 National Semiconductor Corporation
Sensor AFE System: Configurable AFE Potentiostat for
Low-Power Chemical Sensing Applications
General Description
The LMP91000 is a programmable Analog Front End (AFE)
for use in micro-power electrochemical sensing applications.
It provides a complete signal path solution between a sensor
and a microcontroller that generates an output voltage pro-
portional to the cell current. The LMP91000’s programmability
enables it to support multiple electrochemical sensors such
as 3-lead toxic gas sensors and 2-lead galvanic cell sensors
with a single design as opposed to the multiple discrete so-
lutions. The LMP91000 supports gas sensitivities over a
range of 0.5 nA/ppm to 9500 nA/ppm. It also allows for an
easy conversion of current ranges from 5µA to 750µA full
scale.
The LMP91000’s adjustable cell bias and transimpedance
amplifier (TIA) gain are programmable through the the I
terface. The I
nostics. An integrated temperature sensor can be read by the
user through the VOUT pin and used to provide additional
signal correction in the µC or monitored to verify temperature
conditions at the sensor.
The LMP91000 is optimized for micro-power applications and
operates over a voltage range of 2.7V to 5.25V. The total cur-
rent consumption can be less than 10μA. Further power sav-
ings are possible by switching off the TIA amplifier and
shorting the reference electrode to the working electrode with
an internal switch.
Typical Application
2
C interface can also be used for sensor diag-
301325
AFE Gas Detector
2
LMP91000
C in-
Features
Typical Values, T
Applications
Supply voltage
Supply current (average over time)
Cell conditioning current up to
Reference electrode bias current (85°C)
Output drive current
Complete potentiostat circuit to interface to most chemical
cells
Programmable cell bias voltage
Low bias voltage drift
Programmable TIA gain
Sink and source capability
I
Ambient operating temperature
Package
Supported by Webench Sensor AFE Designer
Chemical species identification
Amperometric applications
Electrochemical blood glucose meter
2
C compatible digital interface
A
= 25°C
September 12, 2011
2.75kΩ to 350kΩ
2.7 V to 5.25 V
-40°C to 85°C
www.national.com
900pA (max)
14 pin LLP
30132505
<10 µA
10 mA
750µA