Description
1V Motor/LED control timer ADVANCED COMMUNICATIONS & SENSING
Manufacturer
SEMTECH [Semtech Corporation]
Datasheet
ACS - Revision 2.2
© Semtech Corp.
ADVANCED COMMUNICATIONS & SENSING
Description
The SX8120/21 is a series of 1 V motor/LED control
timers.
The SX8120/21 goes active on the press of a button.
The output goes back to sleep on the next button
press or after a preset time-out (15 sec or 30 sec on
SX8120, 10 minutes or never on the SX8121). The
time-out duration and the motor control polarity are
pin-selected.
When the SX8120/21 is active, it sets its MOTOR
control pin to high or low and sends a burst on its
LED pin to control a LED or boost a command
voltage.
One output goes low when VDD is higher than the
full charge voltage of an NiMH cell to control a
minimal charger.
The SX8120/21 controls its IO state starting at 0.6V to
facilitate power-up.
Functional Block Diagram
SX8120 / SX8121
15 sec / 10 min
Start and Stop
30 sec / None
High
Low
charger
3 - 5V
August 2010
POLARITY
BUTTON
NIMH
TO
(counter )
1.4V
Start/Stop
debounce
Pulse
VDD
+
Page 1
Features
Applications
Ordering Informations
Part number
SX8120ISTRT
SX8121ISTRT
- Available in tape and reel only
- WEEE/RoHS compliant- Pb-Free and Halogen Free.
SX8120/21
polarity
1 V operation
1 button operation
Pin selection of time-out
Pin selection of motor polarity
Boosted LED control (drives bright white and green
NiMH cell charger control (allows USB recharge)
Electric toothbrushes
Electric razors
Toys - LED animation
LED pointer
USB rechargeable
43kHz
LEDS)
Motor
Burst
MOTOR
VDD
VSS
LED
Function
1V motor controller
1V motor controller
1V Motor/LED control timer
1 – 2 V Alkaline
NiMH or NiCd cell
www.semtech.com/products/
SX8120/21
Time out
15 or 30 second
10 minute or none
DATASHEET
Motor

Related parts for SX812X

SX812X Summary of contents

Page 1

ADVANCED COMMUNICATIONS & SENSING Description The SX8120/ series motor/LED control timers. The SX8120/21 goes active on the press of a button. The output goes back to sleep on the next button press or after a ...

Page 2

ADVANCED COMMUNICATIONS & SENSING TABLE OF CONTENT Section ...

Page 3

ADVANCED COMMUNICATIONS & SENSING ELECTRICAL SPECIFICATION 1 Absolute Maximum Ratings Note The Absolute Maximum Ratings, in table below, are stress ratings only. Functional operation of the device at conditions other than those indicated in the Operating Conditions sections of this ...

Page 4

ADVANCED COMMUNICATIONS & SENSING 2 Specifications 2.1 Operating Conditions Note Circuit operates within the Supply Voltage Range VDD-VSS = VDDOC. The specification is verified within the Full Spec Voltage Range VDD-VSS = VDDSPEC. Table 2. Operating range Parameter Supply Voltage ...

Page 5

ADVANCED COMMUNICATIONS & SENSING Table 4. Circuit power consumption specifications Parameter Supply current in Active mode (outputs no loaded, Motor pin on, LED pin bursting, counting) Supply current in Sleep mode (outputs no loaded, Motor pin off, LED pin tied ...

Page 6

ADVANCED COMMUNICATIONS & SENSING 3 Pinout 3.1 SOIC-8 pinout Table 6. SX8120/21 pinout Pin number Pin name 1 TO Digital input 2 BUTTON Digital input 3 POLARITY Digital input 4 NIMH Digital output 5 LED Digital output 6 VSS Power ...

Page 7

ADVANCED COMMUNICATIONS & SENSING TECHNICAL DESCRIPTION 4 System architecture 4.1 SX8120/21 architecture The system is based on an integrated 5% precise counter. It starts and stops pulses based on the command of a button and times-out after a selectable period ...

Page 8

ADVANCED COMMUNICATIONS & SENSING 4.2 SX8120/21 timing and output The following settings are available on the SX8120/21. Table 7. SX8120/21 settings Part number SX8120 SX8121 The timeout and polarity values are set at chip startup and at each start/stop command. ...

Page 9

ADVANCED COMMUNICATIONS & SENSING 4.3 Digital input levels Input thresholds levels scale with VDD. Inputs have an hysteresis based on a Schmitt trigger schematics. 2 1.5 1 Threshold 0.5 0 0.8 4.4 Debounce on BUTTON pin The BUTTON pin is ...

Page 10

ADVANCED COMMUNICATIONS & SENSING 5 Operating Modes VDD 1.05V Switch ON 0.95V Switch OFF 0.9V POR SAFE 0.6V 1. Typical values. 5.1 Safe Mode The internal system goes in Safe mode as soon as the battery voltage is above 0.6-0.7V. ...

Page 11

ADVANCED COMMUNICATIONS & SENSING APPLICATION EXAMPLES 6 Motor and LED timer 6.1 Start/stop a motor with a 30 seconds time-out. TO BUTTON Start/stop button POLARITY NIMH Figure 5. Pressing the button will start the motor for 30 seconds or until ...

Page 12

ADVANCED COMMUNICATIONS & SENSING 6.3 Start/stop a high current motor with 10 minutes time-out TO BUTTON Start/stop button POLARITY NIMH Figure 7. Pressing the button will start the motor for 10 minutes or until the button is pressed again. ACS ...

Page 13

ADVANCED COMMUNICATIONS & SENSING MECHANICAL SPECIFICATION 7 Packages 7.1 SOIC-8 7.1.1 Outline drawing N 2X E/2 1 ccc C 2X N/2 TIPS aaa C SEATING PLANE C SIDE VIEW NOTES: 1. CONTROLLING DIMENSIONS ARE IN MILLIMETERS (ANGLES IN DEGREES). 2. ...

Page 14

ADVANCED COMMUNICATIONS & SENSING 7.1.2 Land pattern This land pattern is for reference purposes only. Consult your manufacturing group to ensure your company’s manufacturing guidelines are met. X (C) P NOTES: 1. THIS LAND PATTERN IS FOR REFERENCE PURPOSES ONLY. ...

Page 15

ADVANCED COMMUNICATIONS & SENSING 7.1.3 SX8120 marking information &&''  $    ACS - Revision 2.2 August 2010 © Semtech Corp. "#$ &&''           !  "#$% !  ...

Page 16

ADVANCED COMMUNICATIONS & SENSING 7.1.4 SX8121 marking information %%&& ACS - Revision 2.2 August 2010 © Semtech Corp. "# %%&&           !  "#$ !  ...

Page 17

ADVANCED COMMUNICATIONS & SENSING © Semtech 2010 All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation ...

Related keywords