HCPL3160 Agilent(Hewlett-Packard), HCPL3160 Datasheet

no-image

HCPL3160

Manufacturer Part Number
HCPL3160
Description
2.0 Amp IGBT Gate Drive Optocoupler with Integrated Over-current Protection and Fault Feedback
Manufacturer
Agilent(Hewlett-Packard)
Datasheet
2.0 Amp IGBT Gate Drive
Optocoupler with Integrated
Over-current Protection and
Fault Feedback
Preliminary Technical Data
• Integrated IGBT
• Integrated Optically Isolated
• CMOS Compatible INPUT
• Small Printed Circuit Board
• -40 C to 100 C Operating
• Suitable for Integration in
• 2.0 A Minimum Peak Output
• 15 kV/ s Minimum Common
• V
1-212
Features
Desaturation Protection
IGBT Fault Status Feedback
and FAULT Status Indicator
Footprint (SO-16 Package)
Temperature
Power Modules
Current
Mode Rejection (CMR) at
V
This data sheet represents the latest information at the time of publication of this catalog. All specifications
subject to change. Samples available Fall 1996.
IORM
CM
= 1500 V
= 890 V
Actual Size
HP 3160
9630
PEAK
Functional Diagram
Description
The HCPL-3160 provides low cost,
area efficient IGBT gate drive
that includes desaturation or over
current detection and local IGBT
shutdown. The integrated fault
feedback optocoupler notifies
the controller when the IGBT is
shutdown due to a desaturation
or over current condition.
1
2
3
4
5
6
7
8
SHIELD
16
15
14
13
12
11
10
9
HCPL-3160
H

Related parts for HCPL3160

HCPL3160 Summary of contents

Page 1

Amp IGBT Gate Drive Optocoupler with Integrated Over-current Protection and Fault Feedback Preliminary Technical Data Features • Integrated IGBT Desaturation Protection • Integrated Optically Isolated IGBT Fault Status Feedback • CMOS Compatible INPUT and FAULT Status Indicator HP 3160 ...

Page 2

Fault Circuit Operation A typical desaturation protected IGBT gate drive application circuit using the HCPL-3160 is shown in Figure 1. The IGBT collector to emitter voltage is monitored through D . DESAT When the IGPT is on and V DESAT ...

Page 3

Preliminary Electrical Specifications (DC) Over recommended operating conditions (T Parameter Symbol Logic Low INPUT Voltages RESET FAULT ENABLE Logic High INPUT Voltages RESET FAULT ENABLE High Level I Output Current Low Level I Output Current High Level V Output Voltage ...

Page 4

Preliminary Switching Specifications (AC) Over recommended operating conditions (T Parameter Symbol Propagation Delay Time t PLH to High Output Level Propagation Delay Time t PHL to Low Output Level Pulse Width Distortion pwd Propagation Delay PHL Difference ...

Related keywords