AT49F010-12JC ATMEL Corporation, AT49F010-12JC Datasheet
AT49F010-12JC
Available stocks
Related parts for AT49F010-12JC
AT49F010-12JC Summary of contents
Page 1
... When the device is deselected, the CMOS standby current is less than 100 A. To allow for simple in-system reprogrammability, the AT49F010/HF010 does not re- quire high input voltages for programming. Five-volt-only commands determine the read and programming operation of the device. Reading data out of the device is similar to reading from an EPROM ...
Page 2
... The typical number of program and erase cycles is in excess of 10,000 cycles. Block Diagram Device Operation READ: The AT49F010/HF010 is accessed like an EPROM. When CE and OE are low and WE is high, the data stored at the memory location determined by the ad- dress pins is asserted on the outputs. The outputs are put in the high impedance state whenever high ...
Page 3
... HARDWARE DATA PROTECTION: Hardware features AT49F010/HF010 in the following ways: ( below 3.8V (typical), the program function is inhib- CC ited ...
Page 4
... MHz OUT -400 -100 4. AT49F010-90 AT49F010 10 OUT High Z High Z ( Manufacturer Code ...
Page 5
... This parameter is characterized and is not 100% tested ACC OE . ACC Output Test Load (1) Typ Max AT49F010/HF010 AT49F010-90 AT49F010-12 Max Min Max Min 70/90/120 Units ...
Page 6
... CS t Chip Select Hold Time CH t Write Pulse Width ( Data Set-up Time Data, OE Hold Time DH OEH t Write Pulse Width High WPH AC Byte Load Waveforms WE Controlled CE Controlled AT49F010/HF010 6 Min Max Units ...
Page 7
... Data Hold Time DH t Write Pulse Width WP t Write Pulse Width High WPH t Erase Cycle Time EC Program Cycle Waveforms Chip Erase Cycle Waveforms Note: OE must be high only when WE and CE are both low. AT49F010/HF010 Min Typ Max Units ...
Page 8
... Notes: 1. These parameters are characterized and not 100% tested. 2. See t spec in AC Read Characteristics Toggle Bit Waveforms Notes: 1. Toggling either both OE and CE will operate toggle bit. The t OEHP met by the toggling input(s). AT49F010/HF010 8 (1) Min 10 10 (2) 0 (1) Min ...
Page 9
... ANY ADDRESS EXIT PRODUCT IDENTIFICATION (4) MODE Notes for boot block lockout feature enable: 1. Data Format: I/O7 - I/O0 (Hex); Address Format: A14 - A0 (Hex). 2. Boot block lockout feature enabled AT49F010/HF010 (1) LOAD DATA AA TO ADDRESS 5555 LOAD DATA 55 TO ADDRESS 2AAA LOAD DATA 80 TO ADDRESS 5555 ...
Page 10
... AT49F010-70JI 32J AT49F010-70PI 32P6 AT49F010-70TI 32T AT49F010-90JC 32J AT49F010-90PC 32P6 AT49F010-90TC 32T AT49F010-90JI 32J AT49F010-90PI 32P6 AT49F010-90TI 32T AT49F010-12JC 32J AT49F010-12PC 32P6 AT49F010-12TC 32T AT49F010-12JI 32J AT49F010-12PI 32P6 AT49F010-12TI 32T Package Type Operation Range Commercial ( Industrial (- Commercial ...