AC-161A ETC1 [List of Unclassifed Manufacturers], AC-161A Datasheet - Page 17

no-image

AC-161A

Manufacturer Part Number
AC-161A
Description
SPECIFICATIONS FOR LCD MODULE
Manufacturer
ETC1 [List of Unclassifed Manufacturers]
Datasheet
High Temperature Operation
Low Temperature Operation
High Temperature Storage
Low Temperature Storage
Thermal Shock Test
Humidity Test
Vibration Test (Packing)
13.6 RELIABILITY
Note 1 : Condensation of water is not permitted on the module.
Note 2 : The module should be inspected after 1 hour storage in normal conditions
Definitions of life end point :
Test Item
l
l
l
l
Current drain should be smaller than the specific value.
Function of the module should be maintained.
Appearance and display quality should not have degraded noticeably.
Contrast ratio should be greater than 50% of the initial value.
(15-35°C , 45-65%RH).
30 m in.
( 1 cycle )
Total 5 cycle
Sweep frequency : 10 ~ 55 ~ 10 Hz/1min
Amplitude : 0.75mm
Test direction : X.Y.Z/3 axis
Duration : 30min/each axis
-20 C ~ 25 C ~ 70 C
Normal Temp. type
-20 3 C , t=96 hrs
50 3 C , t=96 hrs
70 3 C , t=96 hrs
0 3 C , t=96 hrs
AMPIRE CO., LTD.
5 min. 30 min.
40 C, Humidity 90%, 96 hrs
Test Conditions
30 min.
( 1 cycle )
Total 5 cycle
-30 C ~ 25 C ~ 80 C
Extended Temp. type
-20 3 C , t=96 hrs
-30 3 C , t=96 hrs
70 3 C , t=96 hrs
80 3 C , t=96 hrs
5 min. 30 min.
1,2
1,2
1,2
1,2
2
Note
17