MPU150 POWER-ONE [Power-One], MPU150 Datasheet - Page 3

no-image

MPU150

Manufacturer Part Number
MPU150
Description
Power Factor Correction (PFC) Meets EN61000-3-2
Manufacturer
POWER-ONE [Power-One]
Datasheet
PARAMETER
Overvoltage Protection
Overload Protection
Overtemperature Protection
Output Good
Input Power Fail Warning
Current Share
Remote Sense
Inhibit
NOTES: 1) Overvoltage range for 12V, V3 outputs: 14V to 19V.
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
Agency Approvals
Dielectric Withstand Voltage
Electromagnetic Interference
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Input Transient Protection
Insulation Resistance
Leakage Current
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
Altitude
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
OPTIONS
DESCRIPTION
Metric Mounting
CONDITIONS/DESCRIPTION
Latch style overvoltage protection. Available on
V1, V2, all models, and V3 on all models except
MPU150-3300.
MPU150-4350.
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
System shutdown due to excessive internal temperature, automatic reset.
TTL compatible signal available for V1. Signal is high when
output is within 5% of nominal. Signal shall remain low for 20
milliseconds following loss of Output Good.
TTL compatible logic signal. Time before regulation dropout due to loss of input
power. May be used as independent PSOK signal in redundant applications.
Accuracy of shared current with up to 6 parallel units. Single wire current share
on V1 and V2 with return via -Sense return.
Available on V1 and V2. Total voltage compensation for cable losses with
respect to the main output.
Output voltage is inhibited by application of an external high (5V) signal.
CONDITIONS/DESCRIPTION
UL1950.
CSA 22.2 NO. 234/950.
EN60950 (TÜV).
Input to output per EN60950.
FCC CFR title 47 Part 15 Sub-Part J - Conducted.
EN55022 / CISPR 22 Conducted.
Per EN61000-4-2, level 4.
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 3.
Per EN61000-4-5, class 3.
Input to output.
Per EN60950.
CONDITIONS/DESCRIPTION
Operating.
Non-Operating.
Derate linearly above 50°C by 2.5% per °C.
0°C to 70°C (after 15 minute warm-up).
Non-Condensing.
Peak acceleration.
Random vibration, 10Hz to 2kHz, 3 axis.
NOTES
Add “M” as a suffix to the model number to order chassis with
M4 x 0.7 mounting inserts.
®
MPU/MDU150 SERIES
3
12V output, V2 (Note 1)
MPU150 at 264 VAC
MDU150 at 72 VDC
5V output, V1, V2
3.3V output, V1
3.3V output, V2
3.3V output, V1
Line to Ground
At 100% load
At 50% load
Line to Line
MDU150
MPU150
3.3V
5V
(203.2mm x 106.7mm x 38.1mm)
2600
1544
3.16
4.75
MIN
MIN
MIN
-55
4.1
3.8
6.0
4.3
14
10
±2
5
B
B
8
1
2
0
0
5
8.00" x 4.20" x 1.50"
SIZE IMPACT
±0.02
NOM
NOM
NOM
10
10
Approved
±0.05
1250
4.65
4.65
MAX
250
MAX
100
MAX
10k
40k
4.2
6.4
16
50
70
85
95
20
6
ASL Ft.
ASL Ft.
UNITS
UNITS
Class
UNITS
%/°C
%RH
G
VDC
V/M
MΩ
G
mS
mV
kV
kV
kV
µA
°C
°C
°C
%
RMS
V
V
PK

Related parts for MPU150