MPU150-S259 POWER-ONE [Power-One], MPU150-S259 Datasheet - Page 4

no-image

MPU150-S259

Manufacturer Part Number
MPU150-S259
Description
Power Factor Correction (PFC) with a low-profile package
Manufacturer
POWER-ONE [Power-One]
Datasheet
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date
manufactured. Specifications are subject to change without notice.
JUN 08, 2006 revised to JUL 14, 2006
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
Dielectric Withstand Voltage
Electromagnetic Interference
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Input Transient Protection
Insulation Resistance
Leakage Current
Environmental Specifications
PARAMETER
Altitude
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
Options
DESCRIPTION
Metric Mounting
CONDITIONS/DESCRIPTION
UL1950.
CSA 22.2 NO. 234/950.
EN60950 (TÜV).
Input to output per EN60950.
FCC CFR title 47 Part 15 Sub-Part B - Conducted.
EN55022 / CISPR 22 Conducted.
Per EN61000-4-2, level 4.
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 3.
Per EN61000-4-5, class 3.
Input to output.
Per EN60950.
CONDITIONS/DESCRIPTION
Operating.
Non-Operating.
Derate linearly above 50°C by 2.5% per °C.
0°C to 70°C (after 15 minute warm-up).
Non-Condensing.
Peak acceleration.
Random vibration, 10Hz to 2kHz, 3 axis.
NOTES
Add “M” as a suffix to the model number to order chassis with
M4 x 0.7 mounting inserts. Metric mounting inserts are standard for
single-output models MPU150-S259, MPU150-S261, and MPU150-S262.
Page 4 of 6
Single and triple output MPU150 at 264 VAC
Dual output MPU150 at 264 VAC
MDU150:
MDU150:
MPU150:
MPU150:
MPU150/MDU150 Series Data Sheet
MDU150 at 72 VDC
Line to Ground
Line to Ground
At 100% load
At 50% load
Line to Line
Line to Line
MDU150
MPU150
(203.2mm x 106.7mm x 38.1mm)
2600
1544
MIN
0.5
0.5
MIN
-55
10
±2
B
B
8
1
2
0
0
5
(Not required by EN60950)
8.00" x 4.20" x 1.50"
SIZE IMPACT
±0.02
NOM
NOM
10
www.power-one.com
Approved
±0.05
MAX
MAX
10k
40k
1.7
22
50
70
85
95
20
6
ASL Ft.
ASL Ft.
UNITS
Class
UNITS
%/°C
%RH
G
VDC
V/M
M
G
mA
kV
kV
kV
°C
°C
°C
RMS
PK

Related parts for MPU150-S259