LH1301-2R Power-One, LH1301-2R Datasheet

no-image

LH1301-2R

Manufacturer Part Number
LH1301-2R
Description
AC 85..255Vi>12Vo 6A 72 (48)W
Manufacturer
Power-One
Datasheet

Specifications of LH1301-2R

Pack_quantity
5
Lead_time
133
Description
The H Series of AC-DC converters represents a flexible range
of power supplies for use in advanced industrial electronic
systems. Features include high efficiency, reliability, and low
output voltage noise.
The converter inputs are protected against surges and
transients occuring at the source lines. An input over- and
undervoltage lockout circuit disables the outputs, if the input
voltage is outside the specified range. An inrush current
limitation prevents circuit breakers and fuses from tripping at
switch-on.
All outputs are open- and short-circuit proof, and are protected
against overvoltages by means of built-in suppressor diodes.
The outputs can be inhibited by a logic signal applied to the
connector (pin 2). If the inhibit function is not used, pin 2 should
be connected to pin 23 to enable the outputs.
LED indicators display the status of the converter and allow
visual monitoring of the system at any time.
Full input to output, input to case, output to case, and output to
Table of Contents
Description ............................................................................ 1
Model Selection .................................................................... 2
Functional Description .......................................................... 3
Electrical Input Data .............................................................. 4
Electrical Output Data ........................................................... 5
Auxiliary Functions ................................................................ 9
Electromagnetic Compatibility (EMC) ................................. 11
BCD20019 Rev AB
39
1.54"
8 TE
®
6.6"
168
111
4.37"
3 U
Page
Page 1 of 21
Features
output isolation is provided. The converters are designed and
built
IEC/EN 60950-1 and UL/CSA 60950-1, and they are approved
by the safety agencies TÜV and UL.
The case design allows operation at nominal load up to 50 °C
in a free-air ambient temperature. If forced cooling is provided,
the ambient temperature may exceed 50 °C but the case
temperature should remain below 80 °C under all conditions.
A temperature sensor generates an inhibit signal, which
disables the outputs, when the case temperature T
the limit. The outputs automatically recover, when the
temperature drops below the limit.
Two options are available to adapt the converters to individual
applications (D, V).
The converters may either be plugged into 19" rack system
according to IEC 60927-3 or be mounted onto a chassis or a
plate.
Immunity to Environmental Conditions ............................... 12
Mechanical Data ................................................................. 13
Safety and Installation Instructions ..................................... 14
Description of Options ........................................................ 15
Accessories ......................................................................... 20
EC Declaration of Conformity ............................................. 21
• Universal operating input voltage range 85 to 255 VAC
• RoHS lead-solder exemption compliant
• Class I equipment
• 1, 2, or 3 isolated outputs up to 64 V
• Input over- and undervoltage lockout
• Outputs: SELV, no load, overload, short-circuit proof,
• Adjustable output voltages with remote on/off
• Immunity according to IEC/EN 61000-4-2, -3, -4, -5, -6
• Emissions according to EN 55011/55022
• PCBs protected by lacquer
• Battery charger models available
Safety according to IEC/EN 60950-1, UL/CSA 60950-1
rectangular current limiting characteristic
according
to
70 Watt AC-DC Converters
the
international
H Series Data Sheet
www.power-one.com
safety
C
standards
exceeds
Page

Related parts for LH1301-2R

Related keywords