MAX6760TATWD3+ Maxim Integrated Products, MAX6760TATWD3+ Datasheet

no-image

MAX6760TATWD3+

Manufacturer Part Number
MAX6760TATWD3+
Description
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6760TATWD3+

Pack_quantity
1
Comm_code
85423990
Lead_time
119
Eccn
EAR99
The MAX6754–MAX6764 low-power window detectors
monitor undervoltage/overvoltage conditions on system
power supplies. These devices assert when the moni-
tored voltage is under the undervoltage and/or over the
overvoltage thresholds.
The MAX6754–MAX6759/MAX6763/MAX6764 monitor a
single voltage. The MAX6760/MAX6761/MAX6762
monitor dual-voltage systems. The MAX6754/MAX6755/
MAX6756 provide a single undervoltage/overvoltage
output and the MAX6757–MAX6764 provide indepen-
dent undervoltage and overvoltage outputs. The out-
puts are available in push-pull or open-drain
configurations.
The MAX6754–MAX6762 offer factory-fixed voltage
thresholds for monitoring system voltages from 0.9V to
5V with a selectable ±5%, ±10%, or ±15% window volt-
age. The MAX6763/MAX6764 allow for externally
adjustable thresholds. The MAX6754–MAX6762 are
available in two delay timing options (20µs, typ or
100ms, min). The MAX6760/MAX6761/MAX6762 also
include a latched overvoltage output function and the
MAX6754–MAX6762 include a manual reset input.
The family of products is available in small SOT23 and
TDFN packages and is specified over the extended
temperature range of -40°C to +125°C.
19-3075; Rev 3; 12/05
For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at
1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com.
Telecommunications
Networking
Computers/Servers
Data Storage
V
CC
Typical Application Circuit
MR
V
GND
CC
MAX6757
________________________________________________________________ Maxim Integrated Products
Low-Power, Single/Dual-Voltage Window
General Description
SET
UV
OV
Power Metering
DC-DC Converter
Modules
Automotive
Applications
NMI
RESET
µP
♦ Single- or Dual-Supply Voltage Monitors
♦ Factory-Trimmed Window Threshold Options for
♦ Externally Adjustable Window Monitoring Options
♦ Selectable Window Threshold Options (±5%,
♦ Single (Combined UV/OV) or Dual (Separate UV
♦ 20µs (typ) or 100ms (min) Timeout Period Options
♦ Manual Reset Input (MAX6754–MAX6762)
♦ Latched Overvoltage Output Function
♦ Immune to Short Voltage Transients
♦ Low 10µA Supply Current
♦ Low-Voltage Operation (Outputs Valid for V
♦ -40°C to +125°C Operating Temperature Range
♦ Small SOT23 and TDFN Packages
*Insert the threshold level suffixes for V
and 2) after UK, UT, or TA. For the MAX6754–MAX6759, insert
only the V
timeout delay (Table 3) after D to complete the part number. For
example, the MAX6760TALTD3-T provides a V
5V, a V
out period. Sample stock is generally held on standard versions
only (see the Standard Versions table). Standard versions have
an order increment requirement of 2500 pieces. Nonstandard
versions have an order increment requirement of 10,000 pieces.
Contact factory for availability.
Devices are available in both leaded and lead-free packaging.
Specify lead-free by replacing “-T” with “+T” when ordering.
Ordering Information continued at end of data sheet.
Pin Configurations appear at end of data sheet.
MAX6754UK_D_-T
MAX6755UK_D_-T
MAX6756UK_D_-T
MAX6757UT_D_-T
MAX6758UT_D_-T
5V, 3.3V, 3V, 2.5V, 1.8V, 1.5V, 1.2V, and 0.9V
Supplies
for Supplies Down to 0.5V
±10%, ±15%)
and OV) Outputs
(MAX6754–MAX6762)
(MAX6760/MAX6761/MAX6762)
Down to 1V)
CC2
PART*
CC
threshold of 3.3V, and a 100ms minimum reset time-
threshold suffix after the UK or UT. Insert the reset
Ordering Information
-40°C to +125°C
-40°C to +125°C
-40°C to +125°C
-40°C to +125°C
-40°C to +125°C
TEMP RANGE
Detectors
CC
and V
CC
PIN-PACKAGE
5 SOT23-5
5 SOT23-5
5 SOT23-5
6 SOT23-6
6 SOT23-6
CC2
Features
threshold of
(Tables 1
CC
1

Related parts for MAX6760TATWD3+