LV100-100

Manufacturer Part Number
LV100-100
Description
Voltage Transducer LV 100-100
Manufacturer
LEM
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LV100-100
Manufacturer:
LEM
Quantity:
500
Company:
Part Number:
LV100-1000
Quantity:
1 000
Company:
Part Number:
LV100-1000/SP9
Quantity:
1 000
Dimensions LV 100-100
Mechanical characteristics
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
Front view
Top view
General tolerance
Fastening
Connection of primary
Connection of secondary
Connection to the ground
Fastening torque
(in mm. 1 mm = 0.0394 inch)
± 0.3 mm
2 holes
M5 threaded studs
Faston 6.3 x 0.8 mm
M5 threaded stud
2.2 Nm or 1.62 Lb. -Ft.
6.5 mm
Remarks
I
The primary circuit of the transducer must be linked to the
connections where the voltage has to be measured.
This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
S
is positive when V
Secondary terminals
Terminal + : supply voltage + 15 V
Terminal M : measure
Terminal - : supply voltage - 15 V
Terminal
Connection
: ground or earth
P
is applied on terminal +HT.
Left view