The ATR28XXS Series of DC/DC converters feature
high power density and an extended temperature range
for use in military and industrial applications. Designed
to MIL-STD-704D input requirements, these devices
have nominal 28VDC inputs with 3.3V, 5V, 12V and
15V single outputs to satisfy a wide range of requirements.
The circuit design incorporates a pulse width modulated
single forward topology operating in the feed-forward
mode at a nominal switching frequency of 550KHz.
Input to output isolation is achieved through the use of
transformers in the forward and feedback circuits.
The advanced feedback design provides fast loop
response for superior line and load transient characteristics
and offers greater reliability and radiation tolerance
than devices incorporating optical feedback circuits.
Three standard temperature grades are offered with
screening options. Refer to Part Number section. These
devices can be provided in a standard plug-in package
for PC mounting or in a flanged package for more
severe environments.
Manufactured in a facility fully qualified to MIL-PRF-
38534, these converters are fabricated utilizing DSCC
qualified processes. For available screening options,
refer to device screening table in the data sheet.
Variations in electrical, mechanical and screening can
be accommodated.
Extensive computer simulation using complex modeling
enables rapid design modification to be provided.
Contact IR Santa Clara with specific requirements.
Description
www.irf.com
Features
Long Term Hermeticity
Standard Microcircuit Drawings Available
16V to 40VDC Input Range (28VDC Nominal)
3.3V, 5V, 12V and 15V Outputs Available
Indefinite Short Circuit and Overload
Up to 35W/in
30W Output Power Models
Fast Loop Response for Superior Transient
Operating Temperature Range from -55°C to
Popular Industry Standard Pin-Out
Resistance Seam Welded Case for Superior
Ceramic Feed-thru Pins
External Synchronization
Efficiencies up to 84%
Shutdown from External Signal
Military Screening
Protection
Characteristics
+125°C
ATR28XXS SERIES
28V Input, Single Output
3
Power Density
ATR
PD - 94549B
01/15/07
1

Related parts for ATR2803R3S

ATR2803R3S Summary of contents

Page 1

HYBRID-HIGH RELIABILITY DC/DC CONVERTER Description The ATR28XXS Series of DC/DC converters feature high power density and an extended temperature range for use in military and industrial applications. Designed to MIL-STD-704D input requirements, these devices have nominal 28VDC inputs with 3.3V, ...

Page 2

... OUT I = 7500mA 4,5,6 OUT Load step 50% to/from 100% 4,5,6 Load step 50% to/from 100% 4,5,6 Load step 50% to/from 100% 4 5,6 Load step 50% to/from 100% 4 5,6 Input step 16V to/from 4,5,6 40VDC 7500mA OUT ATR2803R3S Device Limits Units Types Min Max 01 3.25 3.35 V 3.20 3.40 01 7500 p-p ± ±30 ± ...

Page 3

... L Unless otherwise specified Input step 16V to/from 4,5,6 40VDC 7500mA OUT I = 10% to 100% of Load 4,5,6 OUT I =0 and 7500mA 4,5,6 OUT 4,5,6 has returned to within ±1. OUT ATR28XXS Series ATR2803R3S Device Limits Units Types Min Max 350 50% load. ...

Page 4

ATR28XXS Series Specifications Absolute Maximum Ratings Input voltage Soldering temperature Operating case temperature Storage case temperature Table II. Electrical performance Characteristics Test Symbol Output voltage V OUT 1 I Output current OUT 2 V Output ripple voltage RIP 3 VR ...

Page 5

Table II. Electrical performance Characteristics - Symbol Recovery time transient step TT LINE line changes Turn on overshoot VTon OS 10 Ton Turn on delay Load fault recovery LF Notes to Specifications 1 ...

Page 6

ATR28XXS Series Specifications Absolute Maximum Ratings Input voltage Soldering temperature Operating case temperature Storage case temperature Table III. Electrical performance Characteristics Test Symbol Output voltage V OUT 1 I Output current OUT 2 V Output ripple voltage RIP 3 VR ...

Page 7

Table III. Electrical performance Characteristics - Test Symbol Recovery time transient TT LINE step line changes Turn on overshoot VTon OS 10 Ton Turn on delay Load fault recovery LF Notes to Specifications ...

Page 8

ATR28XXS Series Specifications Absolute Maximum Ratings Input voltage Soldering temperature Operating case temperature Storage case temperature Table IV. Electrical performance Characteristics Test Symbol Output voltage V OUT 1 I Output current OUT 3 V Output ripple voltage RIP 3 VR ...

Page 9

Table IV. Electrical performance Characteristics - Test Symbol Recovery time transient TT LINE step line changes Turn on overshoot VTon OS 10 Ton Turn on delay Load fault recovery LF Notes to Specifications ...

Page 10

ATR28XXS Series +Input EMI 1 Filter Inhibit Input 2 Case 8 Sync 9 Input Return 10 Application Information Inhibit Function Connecting the inhibit input (Pin 2) to input common (Pin 10) will cause the converter to shut down ...

Page 11

Flanged Ø 0.162 0.050 2 Holes 2.880 2.110 2.550 Max Max 0.390 1.110 Max * If neither remote sense nor voltage trim is used, connect Pin and output voltage will increase by 1.2V. ...

Page 12

ATR28XXS Series Device Screening Requirement MIL-STD-883 Method Temperature Range Element Evaluation MIL-PRF-38534 Non-Destructive 2023 Bond Pull Internal Visual 2017 Temperature Cycle 1010 Constant Acceleration 2001, Y1 Axis PIND 2020 Burn-In 1015 Final Electrical MIL-PRF-38534 ( Group A ) & Specification ...

Related keywords