Description
Solid-state Timer (Miniature Timer with Multiple Time Ranges and Multiple Operating Modes)
Manufacturer
OMRON [Omron Electronics LLC]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
H3YN-21-DC12V
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Miniature Timer with Multiple Time Ranges
and Multiple Operating Modes
• Minimizes stock.
• Pin configuration compatible with MY Power Relay.
• Standard multiple operating modes and multiple time ranges.
• Conforms to EN61812-1 and IEC60664-1 for Low Voltage, and
Model Number Structure
I Model Number Legend
1. Output
2. Time Range
Ordering Information
I List of Models
I Accessories (Order Separately)
Connecting Socket
H3YN-@@-@
Note: Specify both the model number and supply voltage when ordering.
24, 100 to 120, 200 to 230 VAC;
12, 24, 48, 100 to 110, 125 VDC
24 VDC
H3YN-2/-21
H3YN-4/-41
H3YN-4-Z/-41-Z
EMC Directives.
Solid-state Timer
H3YN
2:
4:
None: Short-time range (0.1 s to 10 min)
1:
DPDT
4PDT
Long-time range (0.1 min to 10 hrs)
Supply voltage
Example: H3YN-2 24 VAC
1 2
Timer
3
PYF08A, PYF08A-N,
PYF08A-E
PYF14A, PYF14A-N,
PYF14A-E
Track mounting/Front
Connecting Socket
DPDT
4PDT
4PDT (Twin contacts)
Supply voltage
Time-limit contact
PY08
PY14
Solder terminal
H3YN-2
H3YN-4
H3YN-4-Z
3. Contact Type
Short-time range model
None: Single contact
Z:
(0.1 s to 10 min)
Twin contacts
PY08QN(2)
PY14QN(2)
Back Connecting Socket
Wire-wrap terminal
Solid-state Timer
H3YN-21
H3YN-41
H3YN-41-Z
Long-time range model
PY08-02
PY14-02
(0.1 min to 10 h)
H3YN
PC terminal
B-87

Related parts for H3YN

H3YN Summary of contents

Page 1

... VAC; DPDT 12, 24, 48, 100 to 110, 125 VDC 4PDT 24 VDC 4PDT (Twin contacts) Note: Specify both the model number and supply voltage when ordering. Example: H3YN-2 24 VAC Supply voltage I Accessories (Order Separately) Connecting Socket Timer Track mounting/Front Connecting Socket ...

Page 2

... Control outputs Note: 1. Single-phase, full-wave-rectified power supplies can be used. 2. When using the H3YN continuously in any place where the ambient temperature range of 45°C to 50°C, supply 90% to 110% of the rated supply voltages (supply 95% to 110% with 12 VDC type). 3. Set the reset voltage as follows to ensure proper resetting. ...

Page 3

... Immunity ESD: Immunity RF-interference from AM Radio Waves: Immunity Burst: Immunity Surge: Approved standards UL508, CSA C22.2 No. 14, Lloyds Conforms to EN61812-1 and IEC60664-1. (2.5 kV/2 for H3YN-2/-21, 2.5 kV/1 for H3YN-4/-41, H3YN- 4-Z/-41-Z) Output category according to EN60947-5-1. Note: 1. Terminal screw sections are excluded. 2. Refer to the Life-test Curve. H3YN-2/-21/-4/-41 ...

Page 4

... Reference: A maximum current of 0.5 A can be switched at 125 VDC (cosφ = 1). Maximum current of 0.2 A can be switched if L ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load is 0 VDC (P reference value). H3YN B-90 Solid-state Timer 250 VAC, cosφ = 0.4 5,000 ...

Page 5

... Connections I Connection H3YN-2/-21 DIN Indication Timer circuit UP PW Pulse Operation A pulse output for a certain period can be obtained with a random external input signal. Use the H3YN in interval mode as shown in the following timing charts. H3YN-2/-21 Timer circuit External input H3YN-4/-41 H3YN-4-Z/-41-Z Timer circuit ...

Page 6

... Time limit contact NO (9-5, 10-6, 11-7, 12-8) Run/Power indicator (PW) Output indicator (UP) Power (13-14) Time limit contact NC (9-1, 10-2, 11-3, 12-4) Time limit contact NO (9-5, 10-6, 11-7, 12-8) Run/Power indica- tor (PW) Output indicator (UP) Power (13-14) Time limit contact NC (9-1, 10-2, 11-3, 12-4) Time limit contact NO (9-5, 10-6, 11-7, 12-8) Run/Power indicator (PW) Output indicator (UP) Power (13-14) Time limit contact NC (9-1, 10-2, 11-3, 12-4) Time limit contact NO (9-5, 10-6, 11-7, 12-8) Run/Power indica- tor (PW) Output indicator (UP) H3YN-4/-41 ...

Page 7

... I DIP Switch Settings The 1-s range and ON-delay mode for H3YN-2/-4/-4-Z, the 1-min range and ON-delay mode for H3YN-21/-41/-41-Z are factory-set before shipping. Time Ranges Model Time range Time setting range H3YN- 0 H3YN-4 H3YN-4 min 0 min ...

Page 8

... H3YN-2/-21 Front Mounting H3YN-4/-41 Front Mounting H3YN-4-Z/-41-Z Mounting Height PYF08A/PYF08A-N/PYF08A-E (PYF14A/PYF14A-N/PYF14A-E (see note)) H3YN Series PYF08A (PYF14A) Note: Models in parentheses are Connecting Sockets to the H3YN-4/-41 or H3YN-4-Z/-41-Z. H3YN B-94 Solid-state Timer Eight, 3 × 1.2 elliptic holes 6.4 21.5 max. (63.0) Fourteen, 3 × 1.2 elliptic holes 21.5 max. ...

Page 9

... I Accessories (Order Separately) Connecting Sockets Use the PYF@A, PY@, PY@-02, or PY@QN(2) to mount the H3YN. When ordering any one of these Sockets, replace “@” with “08” or “14.” Track Mounting/Front Connecting Sockets PYF08A Two, 4.2 × 5 3.4 6 mounting holes Eight, M3 × 8 sems 72 max. 23 max. ...

Page 10

... H3YN B-96 Solid-state Timer (Top View) (Top View) Terminal Arrangement Panel Cutout (Bottom View) 25.8 PY08 PY14 Terminal Arrangement (Bottom View) PY08QN PY14QN PY08QN(2) PY14QN(2) Terminal Arrangement (Bottom View) PY08@-02 PY14@-02 Two, 4.5 dia Two, 4.5 dia +0.2 21.4 0 H3YN 59.3 Series +0.2 0 PY@, PY@-02, PY@QN(2) ...

Page 11

... Sockets to be used. PYP-1 Two, 3.4-dia. holes 1.6 Square hole Hold-down Clips The Hold-down Clip makes it possible to mount the H3YN securely and prevent the H3YN from falling out due to vibration or shock. Y92H-3 Y92H-4 3 48.5 25.1 33.5 Note: 1. Push the H3Y in until the Adaptor (Y92F- ...

Page 12

... H3YN and an auxiliary relay, such Relay, in combination. : Auxiliary relay such as MY Relay In the case of the above circuit, the H3YN will be in pulse operation. Therefore, if the circuit shown on page 91 is used, no auxiliary relay will be required. Do not set to the minimum setting in the flicker modes, otherwise the contact may become damaged ...

Related keywords