HFBR-53A3VEM HP [Agilent(Hewlett-Packard)], HFBR-53A3VEM Datasheet - Page 3

no-image

HFBR-53A3VEM

Manufacturer Part Number
HFBR-53A3VEM
Description
3.3 V 1 x 9 Fiber Optic Transceivers for Fibre Channel for Fibre Channel
Manufacturer
HP [Agilent(Hewlett-Packard)]
Datasheet
CAUTION:
There are no user serviceable parts
nor any maintenance required for
the HFBR-53A3VEM/FM. All
adjustments are made at the
factory before shipment to our
customers. Tampering with or
modifying the performance of the
HFBR-53A3VEM/FM will result in
voided product warranty. It may
also result in improper operation
of the HFBR-53A3VEM/FM
circuitry, and possible overstress
of the laser source. Device
degradation or product failure
may result.
Regulatory Compliance
3
Feature
Electrostatic Discharge
(ESD) to the
Electrical Pins
Electrostatic Discharge
(ESD) to the
Duplex SC Receptacle
Electromagnetic
Interference (EMI)
Immunity
Laser Eye Safety
and Equipment Type
Testing
Component
Recognition
MIL-STD-883C
Variation of IEC 801-2
CENELEC EN55022 Class B
Test Method
Method 3015.4
FCC Class B
Variation of IEC 801-3
(CISPR 22A)
VCCI Class I
US 21 CFR, Subchapter J
per Paragraphs 1002.10
and 1002.12
EN 60825-1: 1994 + A11:1996
EN 60825-2: 1994 + A1
EN 60950: 1992 + A1 + A2 + A3
Underwriters Laboratories and
Canadian Standards Association
Joint Component Recognition
for Information Technology
Equipment Including Electrical
Business Equipment.
+A4 + A11
Connection of the
HFBR-53A3VEM/FM to a
nonapproved optical source,
operating above the recom-
mended absolute maximum
conditions or operating the
HFBR-53A3VEM/FM in a manner
inconsistent with its design and
function may result in hazardous
radiation exposure and may be
considered an act of modifying or
manufacturing a laser product.
The person(s) performing such
an act is required by law to
recertify and reidentify the laser
product under the provisions of
U.S. 21 CFR (Subchapter J).
Typically withstand at least 15 kV without
Class 1 (>1500 V)
chassis designs.
Margins are dependent on customer board and
Typically show no measurable effect from a
Performance
damage when the duplex SC connector
receptacle is contacted by a Human Body
Model probe.
10 V/m field swept from 27 to 1000 MHz applied
to the transceiver without a chassis enclosure.
AEL Class I, FDA/CDRH
HFBR-53A3V*M Accession #2071022
AEL Class 1, TUV Rheinland of North America
HFBR-53A3V*M:
Certificate #R9771018.5
Protection Class III
UL File E173874

Related parts for HFBR-53A3VEM