PRAS1 ASM-SENSOR [ASM GmbH], PRAS1 Datasheet - Page 36
PRAS1
Manufacturer Part Number
PRAS1
Description
Angle Sensors and Encoders Contents
Manufacturer
ASM-SENSOR [ASM GmbH]
Datasheet
1.PRAS1.pdf
(52 pages)
POSIROT
PMIS4, PMIR4
Magnetic incremental encoder
36
Outline drawing
Signal wiring
Output signals
Option Z1
(signal Z)
Connection
CAT-PR/PT-E-07
®
Active measurement area
Dimensions in mm [inch]
Signal name
Option
Excitation +
Excitation GND (0 V)
Shield
Z
ERR = status signal, periodical approx. 16 Hz, for side tracking and velocity errors
*
Cable output dimensions
= reference pulse
= status signal ERR available only with HTL (single ended) output
www.asm-sensor.com
Z0
B
A
B
A
–
–
Z1
B
A
B
A
Z
Z
Index mark
Status signal
* = position tolerance of the active
** = less masking tape
ERR
(LED)
Z3 *
B
A
–
Z
–
measurement area:
dx = ±1 mm
cable color
Cable with
open end,
Connector SUB-D (Pin)
View to connector pins
brown
yellow
green
white
black
grey
pink
blue
red
Dimensions informative only.
For guaranteed dimensions
please consult factory.
Connector SUB-D,
15 poles
pin no.
1
1
6
4
7
5
8
9
ASM