Thermal Considerations
Power modules operate in a variety of thermal environments; however, sufficient cooling should always be
provided to help ensure reliable operation.
Considerations include ambient temperature, airflow, module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The
thermal data presented here is based on physical measurements taken in a wind tunnel. The test set-up is
shown below.
The thermal reference points, T
temperatures at this point should not exceed 125
power of the module (Vo,set x Io,max).
Jan. 11, 2010
NON-ISOLATED DC/DC CONVERTERS
6.0 Vdc - 14 Vdc Input, 0.8 Vdc - 2.75 Vdc /30 A Outputs
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 •
Preferred airflow direction and location of hot-spot of the module (Tref).
Wind Tunnel
ref
Q6 & L2 Tref
used in the specifications is shown below. For reliable operation the
PWBs
Thermal Test Setup
o
C. The output power of the module should not exceed the rated
Bel Power Inc., a subsidiary of Bel Fuse Inc.
flow
Air
(0.50)
x
12.7_
(3.0)
76.2_
25.4_
(1.0)
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
AIRFLOW
DIRECTION
www.belfuse.com