LEP100F-24-G RSG [RSG Electronic Components GmbH], LEP100F-24-G Datasheet

no-image

LEP100F-24-G

Manufacturer Part Number
LEP100F-24-G
Description
Rugged PCB type
Manufacturer
RSG [RSG Electronic Components GmbH]
Datasheet
LEP
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
SPECIFICATIONS
MODEL
DC OUTPUT
*1
*2
*3
*4
E-4
Specification is changed at option, refer to Instruction Manual 6.
Peak loading for 10sec. And Duty 35% max, refer to Instruction Manual 5. In detail.
This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to
KEISOKU-GIKEN: RM101).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
R
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
POWER FACTOR
INRUSH CURRENT[A]
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
WATTAGE[W]
LINE REGULATION[mV]
LOAD REGULATION[mV]
RIPPLE[mVp-p]
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 21.4 - 26.4
OUTPUT VOLTAGE SETTING[V] 23.0 - 25.0
OVERCURRENT PROTECTION Works over 101% of peak current and recovers automatically
OVERVOLTAGE PROTECTION
REMOTE ON/OFF
INPUT-OUTPUT - RC
INPUT-FG
OUTPUT - RC-FG
OUTPUT-RC
OPERATING TEMP. , HUMID.AND ALTITUDE -10 to +70 C , 20 - 90%RH ( Non condensing ) ( Refer to DERATING CURVE ), 3 , 000m ( 10 , 000feet ) max
STORAGE TEMP. , HUMID.AND ALTITUDE -20 to +75 C , 20 - 90%RH ( Non condensing ), 9 , 000m ( 30 , 000feet ) max
VIBRATION
IMPACT
AGENCY APPROVALS
CE MARKING
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
LEP100F
Rugged PCB type
ACIN 100V 1.4typ ( Io=100% )
ACIN 200V 0.7typ ( Io=100% )
ACIN 100V 81typ ( Io=100% )
ACIN 200V 84typ ( Io=100% )
ACIN 100V 0.98typ ( Io=100% )
ACIN 200V 0.93typ ( Io=100% )
ACIN 100V 15typ ( Io=100% ) ( At cold start ) ( Ta=25 C )
ACIN 200V 30typ ( Io=100% ) ( At cold start ) ( Ta=25 C )
0 to +50 C
-10 - 0 C
0 to +50 C
-10 - 0 C
0 to +50 C 120max
-10 to +50 C 145max
* 2
* 3
* 3
* 3
* 3
* 4
* 5
* 5
* 5
LEP100F-24
+24V 4.2 ( Peak 7 ) A
LEP100F-24
AC85 - 264 1 f or DC 120 - 370
50/60 ( 47 - 63 ) or DC
0.75max ( 60Hz , According to IEC60950 and DEN-AN )
+24
0 - 4.2 ( Peak 7 )
100.8 ( Peak 168 )
48max
76max
120max
160max
150max
180max
48max
500max ( ACIN 100V , Io=100% )
20typ ( ACIN 100V , Io=100% )
Works at 115 - 140% of rating
Option ( Refer to Instruction Manual )
AC3 , 000V 1minute , Cutoff current = 10mA , DC500V 50M W min ( At Room Temperature )
AC2 , 000V 1minute , Cutoff current = 10mA , DC500V 50M W min ( At Room Temperature )
AC500V 1minute , Cutoff current = 100mA , DC500V 50M W min ( At Room Temperature )
AC100V 1minute , Cutoff current = 100mA , DC100V 10M W min ( At Room Temperature )
10 - 55Hz , 19.6m/s
196.1m/s
UL60950-1 , C-UL ( CSA60950-1 ), EN60950-1 , EN50178 Complies with DEN-AN and IEC60950-1 ( At only AC input )
Low Voltage Directive , EMC Directive
Complies with FCC-B , CISPR22-B , EN55022-B , VCCI-B
Complies with IEC61000-3-2
75 X 35 X 222mm ( W X H X D ) /380g max ( without chassis and cover )
Convection
2
( 20G ), 11ms , once each X , Y and Z axis
2
( 2G ), 3minutes period , 60minutes each along X , Y and Z axis
*5
*
*
*
LEP100F-36
+36V 2.8 ( Peak 4.7 ) A
LEP100F-36
82typ ( Io=100% )
85typ ( Io=100% )
+36
0 - 2.8 ( Peak 4.7 )
100.8 ( Peak 169.2 )
48max
90max
120max
160max
150max
180max
150max
180max
48max
26.4 - 39.6
35.0 - 37.0
1
Applicable when remote control (optional) is added.
Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
A sound may occur from power supply at peak loading.
LEP 100
Ordering information
2
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The Noise Filter is recommended
*to connect with several devices.
Recommended Noise Filter
NAC-06-472
3
F
LEP100F-48
+48V 2.1 ( Peak 3.5 ) A
LEP100F-48
83typ ( Io=100% )
85typ ( Io=100% )
+48
0 - 2.1 ( Peak 3.5 )
100.8 ( Peak 168 )
48max
150max
150max
300max
250max
350max
240max
300max
48max
39.6 - 52.8
46.0 - 50.0
4
-24
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional
G :Low leakage current
R :with Remote ON/OFF
S :with Chassis
SN:with Chassis & cover
T :Vertical terminal block
U :Operating stop voltage
Z :with ZT
5
is set at a lower value
-O
*
1

Related parts for LEP100F-24-G

LEP100F-24-G Summary of contents

Page 1

... High voltage pulse noise type : NAP series T :Vertical terminal block Low leakage current type : NAM series U :Operating stop voltage *The Noise Filter is recommended is set at a lower value *to connect with several devices. Z :with ZT LEP100F-48 +48V 2.1 ( Peak 3 LEP100F-48 83typ ( Io=100% ) 85typ ( Io=100 2.1 ( Peak 3.5 ) 100.8 ( Peak 168 ) ...

Page 2

... Chain : SXH-001T-P0.6 B2B-XH-A XHP-2 (Option) Loose: BXH-001T-P0.6 CN4 Chain : SXH-001T-P0.6 B3B-XH-A XHP-3 (Option) Loose: BXH-001T-P0.6 (Mfr: J.S.T.) Performance data ¡ RISE TIME & FALL TIME ( LEP100F- Output AC Input 100ms/DIV ¡ INPUT HARMONIC CURRENT ( LEP100F- Harmonic current standard class A Load factor 1 Input voltage AC 0.1 0.01 0.001 ...

Related keywords