JUN 07, 2006 revised to AUG 10, 2006
Multiple Output Model Selection (Cont.)
MAP80-4010
MAP80-4020
NOTES:
Input Specifications
PARAMETER
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Operating Frequency
Output Specifications
PARAMETER
Efficiency
Minimum Loads
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-On Delay
Turn-on Rise Time
Interface Signals and Internal Protection
PARAMETER
Overvoltage
Protection
Overload Protection
Power Fail
Warning (Note 1)
NOTES:
MODEL
1) Peak loads up to 90 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 90 Watts.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
1) Power Fail Warning is not available on MAP80-1024. The MAP80-1012 is an open collector output, capable of sinking 35 mA, maximum.
VOLTAGE
OUTPUT
+12V
+12V
-12V
-12V
+5V
+5V
-5V
-5V
11.52V to 12.48V
11.52V to 12.48V
CONDITIONS/DESCRIPTION
Continuous input range.
AC input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Nominal AC input voltage (115VAC), full rated load.
90 VAC (80W load).
110VAC (80W load).
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 264VAC (one cycle). 25° C.
Switching frequency of power supply (varies with load).
CONDITIONS/DESCRIPTION
Full load, 115VAC. Varies with distribution of loads among outputs.
MAP80-1012
MAP80-1024
MAP80-1005 and all multiple output models, main channel only.
Full load, 20MHz bandwidth.
Continuous output power, all multiple output models.
Peak output power (60s maximum, 10% duty cycle), all multiple output models.
Output voltage overshoot/undershoot at turn-on, V1, V2.
Varies by output. Total regulation includes: line changes from 90-132 VAC
or 175-264, changes in load starting at 20% load and changing to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output of multiple output units).
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
CONDITIONS/DESCRIPTION
Provided on MAP80-1005 and the main output of multiple output units.
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
TTL compatible logic signal. Time before regulation dropout
due to loss of input power at 110VAC.
4.8V to 5.5V
4.8V to 5.5V
ADJUSTMENT
RANGE
Fixed
Fixed
Fixed
Fixed
CURRENT
OUTPUT
14A
14A
4A
1A
3A
4A
1A
3A
80W Continuous Output Power
Page 2 of 4
CURRENT (NOTE 1)
PEAK OUTPUT
16A
16A
7A
1A
3A
7A
1A
3A
MAP80 AC-DC Series Data Sheet
REGULATION
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
MAP80-1012
MAP80-1024
LINE
REGULATION
LOAD
2%
2%
2%
2%
1%
1%
1%
1%
0.42
0.21
1.00
175
MIN
MIN
MIN
5.5
90
47
90
20
22
73
17
32
1
4
RIPPLE & NOISE
%p-p (NOTE 2)
NOM
NOM
NOM
1%
1%
1%
1%
1%
1%
1%
1%
75
See Model Selection Chart.
See Model Selection Chart.
www.power-one.com
MAX
135
264
120
MAX
500
MAX
-11.5V to -12.5V
-11.5V to -12.5V
2.5
1.8
6.8
45
80
80
90
63
20
23
37
12.0V to 12.1V
12.0V to 12.1V
1
5
-4.8V to -5.4V
-4.8V to -5.4V
INITIAL SETTING
5.1V to 5.2V
5.1V to 5.2V
ACCURACY
Amps
Watts
Watts
UNITS
A
UNITS
UNITS
VAC
VAC
A
kHz
Sec
mS
mS
mS
Hz
µS
RMS
%
%
V
PK