AAT4618IJS-0.5-1-T1 ANALOGICTECH [Advanced Analogic Technologies], AAT4618IJS-0.5-1-T1 Datasheet - Page 9

no-image

AAT4618IJS-0.5-1-T1

Manufacturer Part Number
AAT4618IJS-0.5-1-T1
Description
Current Limited Load Switch
Manufacturer
ANALOGICTECH [Advanced Analogic Technologies]
Datasheet
AAT4618 would be if the AAT4618 were not dissi-
pating power. Equation 1 can be rearranged to
solve for I
T
activate the AAT4618 over-temperature protection.
With the typical specification of 125°C, 115°C is a
safe minimum value to use.
4618.2006.05.1.2
SD(MIN)
Eq. 2:
is the minimum temperature required to
MAX
, as shown in Equation 2.
I
MAX
=
R
T
DS(ON)(MAX)
SD(MIN)
- T
A(MAX)
· R
ΘJA
For example, if an application is specified to oper-
ate in 50°C environments, the PCB operates at
temperatures as high as 85°C. The application is
sealed and its PCB is small, causing R
approximately 150 °C/W. Using Equation 2,
The AAT4618 is safe to operate at the minimum
current limit level of 500mA at 85°C.
Eq. 3:
Current Limited Load Switch
I
MAX
=
220 · 150
115 - 85
= 950mA
AAT4618
θJA
to be
9

Related parts for AAT4618IJS-0.5-1-T1