... INSTALLATION INSTRUCTIONS Part Numbers: P110-6000 (INTELLIMIST Humidifier and Humidistat) P110-6001 (INTELLIMIST Humidifier and INTELLISTAT™ Control) CONTENTS SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 INSTALLATION 1-4 Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Humidifier and Filter Installation . . . . . . . . . . . . . . . . . . . . . . . .2 Water Supply Connection Drainage Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Humidistat or INTELLISTAT Control Configuration OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 SAFETY CONSIDERATIONS Installation and servicing of air-conditioning equipment can be hazardous due to system pressure and electrical compo- nents ...
Page 2
... R Humidifer C MODEL: P110-300 3.50” LISTED DOUBLE O-RING PUSH-IN CONNECTOR COLLET 3.50” 1” DIA. DOUBLE O-RING PUSH-IN CONNECTOR COLLET 2.75” 10.25” Fig. 1 — Humidifier Dimensions Humidifier and Filter Installation — following procedure to install the humidifier and filter: 1. Turn off all power to HVAC equipment. ...
Page 3
... Water damage may result if a drain pan is not provided under the humidifier installation location. Wiring — The humidifier is wired differently when con- nected to the P110-0009 Humidistat, and the P374-1600 INTELLISTAT™ control. Refer to the respective Installation Instructions. Use field-supplied wire. Follow NEC (National Electric Code) and all local codes ...
Page 4
... NOTE: The C and R terminals on the INTELLIMIST™ humidifier are not connected internally. They are provided for an easy ‘tie-off point’ when using one multi-conductor cable from the humidifier to the Humidistat. In this case H2 would need a jumper to C. Fig. 6C — Wiring to P110-0009 Humidistat (Without Thermostat, Terminals R and C Are Used) THERMOSTAT R ...
Page 5
OPERATION To start up the humidifier, open all supply water valves to allow water flow to the humidifier. Set the Humidistat or INTELLISTAT™ control to highest demand (99% humidity). When the humidifier is on (mist spray is activated), the red ...
Page 6
... The lower air temperature of the heated air absorbs less water. Verify that either the Totaline Humidistat (P110-0009) or INTELLISTAT™ control (P374-1600) are being used. Any other controller will cause a continuous (non- pulsed) spray. ...
Page 7
INTELLIMIST™ RESIDENTIAL ATOMIZING HUMIDIFIER One-Year Warranty — This CARRIER CORPORATION (herein referred to as “COMPANY”) product is warranted to be free from defects in material and workmanship appears within one year from the date of original installa- tion, ...
Page 8
ALL Totaline® products are backed with a one-year warranty by Carrier Corporation, the world’s largest manufacturer of air conditioning, heating, and refrigeration products. Manufacturer reserves the right to REPLACEMENT COMPONENTS DIVISION discontinue, or change at any time, © CARRIER CORPORATION ...