P110-6000 ETC1 [List of Unclassifed Manufacturers], P110-6000 Datasheet

no-image

P110-6000

Manufacturer Part Number
P110-6000
Description
INTELLIMISTTM Residential Atomizing Humidifier and Control
Manufacturer
ETC1 [List of Unclassifed Manufacturers]
Datasheet
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Humidifier and Filter Installation . . . . . . . . . . . . . . . . . . . . . . . .2
Water Supply Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Drainage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Humidistat or INTELLISTAT Control
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
be hazardous due to system pressure and electrical compo-
nents. Only trained and qualified service personnel should in-
stall, repair, or service air-conditioning equipment.
tions such as changing filters. All other operations should be
performed by trained service personnel. When working on air-
conditioning equipment, observe precautions in the literature,
tags and labels attached to the unit or accessory, and other safe-
ty precautions that may apply.
gloves.
The INTELLIMIST humidifier is normally located in the
supply plenum and adds up to 24 gallons of humidity per day
to the supply air using MICROPULSE™ technology to assure
maximum efficiency. The INTELLIMIST humidifier is
designed for use with 1 to 7.5 ton HVAC systems. Only the
following controls may be used with the INTELLIMIST hu-
midifier: the P110-0009 Humidistat, and the P374-1600
INTELLISTAT combination temperature and humidity con-
trol. Humidifier dimensions are shown in Fig. 1.
Before installing an accessory or performing maintenance
or service on humidifier, turn off main power switch to
unit. Electrical shock can cause injury or death. There may
be more than one disconnect switch.
Do not use the humidifier with any non-approved humidi-
stat or control. Damage to the unit may result.
Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Installation and servicing of air-conditioning equipment can
Untrained personnel can perform basic maintenance func-
Follow all safety codes. Wear safety glasses and work
The INTELLIMIST humidifier is an atomizing humidifier.
Part Numbers: P110-6000 (INTELLIMIST Humidifier and Humidistat)
specifications or designs without notice
discontinue, or change at any time,
Manufacturer reserves the right to
and without incurring obligations.
SAFETY CONSIDERATIONS
CONTENTS
GENERAL
P110-6001 (INTELLIMIST Humidifier and INTELLISTAT™ Control)
INSTALLATION
INSTRUCTIONS
REPLACEMENT COMPONENTS DIVISION
© CARRIER CORPORATION 5-01
PRINTED IN U.S.A.
Page
NOTE: Refer to Humidistat or INTELLISTAT control Installa-
tion and Operating Instructions for more information on those
devices.
*Contains the following: self-piercing valve, rubber gasket, 2 bolts
Location —
cated on the supply air plenum. Use only with central air-
conditioning systems. See Fig. 2.
quirements. Ensure that there is adequate clearance for service.
tures may occur. Do not install on furnace jacket or where hu-
midifier or components may be exposed to hot surfaces.
filter, and water line away from furnace exhaust vent.
and nuts, flange, brass nut, brass ferrule, brass insert.
The humidifier must be mounted over the evaporator coil
or evaporator coil drain pan. Water damage may result.
Adequate air and moisture mixing is essential to ensure that
water does not accumulate in ductwork.
Always install downstream of electric heat elements and
electronic air cleaner.
Make sure site can be supplied with the necessary power re-
Humidifier must not be installed where freezing tempera-
On vertical equipment, allow clearance for the humidifier,
QUANTITY
1
1
1
1
1
1
1
Humidifier and Control
Residential Atomizing
PACKAGE CONTENTS
The INTELLIMIST humidifier should be lo-
INSTALLATION
Humidifier
Humidistat (P110-6000) or
INTELLISTAT Control (P110-6001)
Spray Nozzle
1
In-Line Water Filter
Water Filter Mounting Bracket
Mounting Kit Containing:
1 — Humidifier Mounting Template
8 — No. 6 Mounting Screws
2 — Threaded Adapters
3 — Locking Nuts
1 — Self Piercing Valve Installation Kit*
1 — Teflon Tape
2 — Plastic Water Filter Mounting Bands
/
4
-in. OD Plastic Tubing (20 ft)
LITERATURE NUMBER HUM-55SI
INTELLIMIST™
CATALOG NUMBER 570-452
REPLACES: HUM-53SI
ITEM

Related parts for P110-6000

P110-6000 Summary of contents

Page 1

... INSTALLATION INSTRUCTIONS Part Numbers: P110-6000 (INTELLIMIST Humidifier and Humidistat) P110-6001 (INTELLIMIST Humidifier and INTELLISTAT™ Control) CONTENTS SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 INSTALLATION 1-4 Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Humidifier and Filter Installation . . . . . . . . . . . . . . . . . . . . . . . .2 Water Supply Connection Drainage Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Humidistat or INTELLISTAT Control Configuration OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 SAFETY CONSIDERATIONS Installation and servicing of air-conditioning equipment can be hazardous due to system pressure and electrical compo- nents ...

Page 2

... R Humidifer C MODEL: P110-300 3.50” LISTED DOUBLE O-RING PUSH-IN CONNECTOR COLLET 3.50” 1” DIA. DOUBLE O-RING PUSH-IN CONNECTOR COLLET 2.75” 10.25” Fig. 1 — Humidifier Dimensions Humidifier and Filter Installation — following procedure to install the humidifier and filter: 1. Turn off all power to HVAC equipment. ...

Page 3

... Water damage may result if a drain pan is not provided under the humidifier installation location. Wiring — The humidifier is wired differently when con- nected to the P110-0009 Humidistat, and the P374-1600 INTELLISTAT™ control. Refer to the respective Installation Instructions. Use field-supplied wire. Follow NEC (National Electric Code) and all local codes ...

Page 4

... NOTE: The C and R terminals on the INTELLIMIST™ humidifier are not connected internally. They are provided for an easy ‘tie-off point’ when using one multi-conductor cable from the humidifier to the Humidistat. In this case H2 would need a jumper to C. Fig. 6C — Wiring to P110-0009 Humidistat (Without Thermostat, Terminals R and C Are Used) THERMOSTAT R ...

Page 5

OPERATION To start up the humidifier, open all supply water valves to allow water flow to the humidifier. Set the Humidistat or INTELLISTAT™ control to highest demand (99% humidity). When the humidifier is on (mist spray is activated), the red ...

Page 6

... The lower air temperature of the heated air absorbs less water. Verify that either the Totaline Humidistat (P110-0009) or INTELLISTAT™ control (P374-1600) are being used. Any other controller will cause a continuous (non- pulsed) spray. ...

Page 7

INTELLIMIST™ RESIDENTIAL ATOMIZING HUMIDIFIER One-Year Warranty — This CARRIER CORPORATION (herein referred to as “COMPANY”) product is warranted to be free from defects in material and workmanship appears within one year from the date of original installa- tion, ...

Page 8

ALL Totaline® products are backed with a one-year warranty by Carrier Corporation, the world’s largest manufacturer of air conditioning, heating, and refrigeration products. Manufacturer reserves the right to REPLACEMENT COMPONENTS DIVISION discontinue, or change at any time, © CARRIER CORPORATION ...