EXB30-48S2V0J Emerson, EXB30-48S2V0J Datasheet

no-image

EXB30-48S2V0J

Manufacturer Part Number
EXB30-48S2V0J
Description
DC-DC / Industry Standard Isolated Half Brick
Manufacturer
Emerson
Datasheet
EXB30 Series
The EXB30 is a new high efficiency open frame isolated 30 Watt converter series in an
industry standard footprint. The first five models in the series feature a 2:1 input voltage
range of 36 Vdc to 75 Vdc and are available in output voltages of 12 V, 5 V, 3.3 V, 2.5 V
and 2 V. Each model is trimmable from 80% to 110% except the 12 V output which has
a wider trim range of 60% to 110%. The sub 5 V models have an output current rating
of 8 A. Typical efficiencies for the models are 92% for the 5 V, 90% for the 3.3 V and
12 V, 87% for the 2.5 V and 86% for the 2 V version. The EXB30 series offers remote
ON/OFF and remote sense compensation to correct for voltage drops at the load.
Overcurrent, overvoltage and overtemperature protection features are included as
standard. With full international safety approval including EN60950 and cUL1950, the
EXB30 reduces compliance costs and time to market.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
DC-DC CONVERTERS
OUTPUT SPECIFICATIONS
Voltage adjustability
Set point accuracy
Line regulation
Load regulation
Total error band
Minimum load
Overshoot
Undershoot
Ripple and noise
(See Note 1)
Temperature coefficient
Transient response
(See Note 2)
Remote sense
INPUT SPECIFICATIONS
Input voltage range
Input current
Input current (max.)
(See Note 4)
Input reflected ripple
Active high remote ON/OFF
Logic compatibility
ON
OFF
Undervoltage lockout
Start-up time
(See Note 7)
High efficiency topology, 92% typical at 5 V
Industry standard footprint
Wide operating temperature, -40 ˚C to +85 ˚C
(natural convection)
80% to 110% output trim
No minimum load
Overvoltage and overtemperature protection
Remote sense compensation
Remote ON/OFF
Available RoHS compliant
Low line to high line
Full load to min. load
At turn-on and turn-off
5 Hz to 20 MHz
48 Vin nominal
No load
Remote OFF
48 V models
(See Note 6)
48 Vin: power up
48 Vin: power down
Power up
Remote ON/OFF
S i n g l e o u t p u t
16-30 W High Efficiency DC-DC Converters
10% output voltage change
Open collector ref to -input
Open circuit or >2 Vdc
within total error band
1.0 A max. @ Io max.
2.0% max. deviation
and Vin = 36-75 Vdc
300 µs recovery to
30 mA (pk-pk) typ.
150 mV pk-pk
80% to 110%
±1.5% max.
50 mA max.
10 mA max.
±0.02%/°C
0.1% max.
0.2% max.
20 mV rms
36-75 Vdc
<1.2 Vdc
±3.0%
31.5 V
30 ms
30 ms
None
None
34 V
0%
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
Immunity:
ESD air
ESD contact
Radiated field enclosure EN61000-4-3
Conducted (DC power)
Conducted (signal)
Input transients
GENERAL SPECIFICATIONS
Efficiency
Basic insulation
Switching frequency
Approvals and
standards
(See Note 5)
Material flammability
Weight
MTBF
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
ETS 300 019-2-3
Altitude
EN55022 (See Note 3)
EN55022 (See Note 3)
EN55022 (See App. Note 108)
EN61000-4-2
EN61000-4-2
EN61000-4-6
EN61000-4-6
ETS 300 132-2, ETR 283
Input/output
Fixed
MIL-HDBK-217F
@ 25 °C, 100% load
ground benign
Operating ambient
temperature
Non-operating
Operating
Non-operating
File Name: exb30s.pdf Rev: 05 Dec 2005
SPECIFICATIONS
8 kV (NP), 15 kV (RP)
IEC950, UL/cUL1950
2 YEAR WARRANTY
Classes T3.1 to T3.5
6 kV (NP), 8 kV (RP)
VDE0805, EN60950
CSA C22.2 No. 950
-40 °C to +125 °C
-40 °C to +85 °C
10,000 feet max.
40,000 feet max.
>300,000 hours
40 g (1.41 oz)
300 kHz typ.
10 V/m (NP)
1500 Vdc
10 V (NP)
10 V (NP)
See table
UL94V-0
Level A
Level B
Level B
1

Related parts for EXB30-48S2V0J

EXB30-48S2V0J Summary of contents

Page 1

... The sub 5 V models have an output current rating Typical efficiencies for the models are 92% for the 5 V, 90% for the 3.3 V and 12 V, 87% for the 2.5 V and 86% for the 2 V version. The EXB30 series offers remote ON/OFF and remote sense compensation to correct for voltage drops at the load. ...

Page 2

... A H inductor in series with +Vin. Continuous Non-latching clamp automatic recovery and current requirements   Application Note Longform Datasheet REGULATION MODEL (TYP.) NUMBER LINE LOAD 86% ±0.1% ±0.2% EXB30-48S2V0J 87% ±0.1% ±0.2% EXB30-48S2V5J 90% ±0.1% ±0.2% EXB30-48S3V3J 92% ±0.1% ±0.2% EXB30-48S05J 90% ±0.1% ±0.2% EXB30-48S12J OPEN-FRAME HEIGHT ø0.040 ±0.002 (ø ...