UT54ACS109 AEROFLEX [Aeroflex Circuit Technology], UT54ACS109 Datasheet
UT54ACS109
Related parts for UT54ACS109
UT54ACS109 Summary of contents
Page 1
... DIP - 16-lead flatpack DESCRIPTION The UT54ACS109 and the UT54ACTS109 are dual J-K posi- tive triggered flip-flops. A low level at the preset or clear inputs sets or resets the outputs regardless of the other input levels. When preset and clear are inactive (high), data at the J and K input meeting the setup time requirements are transferred to the outputs on the positive-going edge of the clock pulse ...
Page 2
... Exposure to absolute maximum rating conditions for extended periods may affect device reliability. RadHard MSI Logic 1 LIMIT 1.0E6 80 120 1.0E14 PARAMETER Supply voltage Voltage any pin Storage Temperature range Maximum junction temperature DC input current Maximum power dissipation UT54ACS109/UT54ACTS109 Q Q UNITS rads(Si) 2 MeV-cm /mg 2 MeV-cm /mg 2 n/cm LIMIT UNITS -0 ...
Page 3
... UT54ACS109/UT54ACTS109 RECOMMENDED OPERATING CONDITIONS SYMBOL PARAMETER Supply voltage Input voltage any pin Temperature range LIMIT UNITS 4 125 C RadHard MSI Logic ...
Page 4
... 50pF 5.5V DD For input under test For all other inputs 5. 1MHz @ 1MHz @ 0V UT54ACS109/UT54ACTS109 MIN MAX 0.8 .3V . 0.40 0.25 . 0.25 DD and V -200 200 0.4V 2.0 1.6 - 2.1V ...
Page 5
... UT54ACS109/UT54ACTS109 Notes: 1. Functional tests are conducted in accordance with MIL-STD-883 with the following input test conditions 50%, as specified herein, for TTL, CMOS, or Schmitt compatible inputs. Devices may be tested using any input voltage within the above specified range, but are guaranteed to V (min) and V (max) ...
Page 6
... All specifications valid for radiation dose 1E6 rads(Si). 3. Based on characterization, hold time ( 0ns can be assumed if data setup time (t H RadHard MSI Logic 2 < +125 C) C PARAMETER ) is >10ns. This is guaranteed, but not tested. SU2 UT54ACS109/UT54ACTS109 MINIMUM MAXIMUM ...