G6B-1114C-US ETC1 [List of Unclassifed Manufacturers], G6B-1114C-US Datasheet - Page 3

no-image

G6B-1114C-US

Manufacturer Part Number
G6B-1114C-US
Description
Sub-miniature Relay that Switches up to 5 A
Manufacturer
ETC1 [List of Unclassifed Manufacturers]
Datasheet
Note: P level: λ 60 = 0.1 x 10
Note: The data shown above are initial values.
Load
Rated load
Contact material
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Failure rate (reference value)
Load
Rated load
Contact material
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Failure rate (reference value)
Operate (set) time
Release (reset) time
Min. set/reset signal width
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
PCB Power Relay – G6B
66
Contact Ratings
Characteristics
Contact resistance
Item
Item
-6
/operation
Resistive load
(cosø = 1)
5 A at 250 VAC;
5 A at 30 VDC
AgCdO (Cd free planned 1 Apr 05)
5 A
380 VAC, 125 VDC
5 A
1,250 VA, 150 W
10 mA at 5 VDC
Resistive load (cosø = 1)
8 A at 250 VAC; 5 A at 30 VDC
AgCdO
8 A
380 VAC, 125 VDC
8 A
2,000 VA, 150 W
10 mA at 5 VDC
10 ms max. (mean value: 1-pole approx. 3 ms, 2-pole approx. 4 ms)
Single-side stable types: 10 ms max. (mean value: 1-pole approx. 1 ms, 2-pole approx. 2 ms)
Latching types: 10 ms max. (mean value: approx. 3 ms)
Latching type: 15 ms min. (at 23˚C)
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
1,000 MΩ min. (at 500 VDC, at 250 VDC between set coil and reset coil)
3,000 VAC (Latching types: 2,000 VAC), 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
250 VAC, 50/60 Hz for 1 min between set and reset coils
2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
Destruction: 10 to 55 to 10 Hz, 0.75mm single amplitude (1.5mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75mm single amplitude (1.5mm double amplitude)
Destruction: 1,000 m/s
Malfunction: Single-side stable: 100 m/s
Mechanical: 50,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operation min. (at 1,800 operations/hr)
Operating: -25°C to 70°C (with no icing)
Operating: 5% to 85%
Double-winding latching: Approx. 3.7 g
High-capacity: Approx. 4.6 g
Double pole: Approx. 4.5 g
Other: Approx. 3.5 g
SPST-NO
Inductive load
(cosø = 0.4; L/R = 7 ms)
2 A at 250 VAC;
2 A at 30 VDC
500 VA, 60 W
2
SPST-NO (High-capacity)
2
; Latching: 300 m/s
30 mΩ max.
Resistive load
(cosø = 1)
5 A at 250 VAC;
5 A at 30 VDC
1,250 VA, 150 W
Inductive load (cosø = 0.4; L/R = 7 ms)
2 A at 250 VAC; 2 A at 30 VDC
SPST-NO + SPST-NC, DPST-NO, DPST-NC
2
Inductive load
(cosø = 0.4; L/R = 7 ms)
1.5 A at 250 VAC;
1.5 A at 30 VDC
375 VA, 80 W

Related parts for G6B-1114C-US