VOF-80 CUI [CUI INC], VOF-80 Datasheet

no-image

VOF-80

Manufacturer Part Number
VOF-80
Description
switching power supply
Manufacturer
CUI [CUI INC]
Datasheet
PART NUMBER: VOF-80
features
• no-load power consumption < 0.5W
• universal input 85~264 V ac
• over current, over voltage protected
• industry standard footprint
• efficiency up to 89%
• safety approved to CB, TUV, CE, UL/cUL
• conducted EMI meets EN55022 class B and FCC class B
MODEL
VOF-80-3.3
VOF-80-5
VOF-80-12
VOF-80-15
VOF-80-24
VOF-80-48
notes:
INPUT
parameter
input frequency
input voltage
input current
inrush current
input fuse
OUTPUT
parameter
efficiency
hold up time
adjustability
temp. coefficient
PROTECTION CIRCUIT
parameter
output overload
output over voltage output voltage is limited by TVS clamping to: 6.8 V for 3.3 & 5 V models, 135% for all other models
output short circuit
20050 SW 112
1. Measured from high line to low line at rated load.
2. Measured from full load to 10% load at 115 V ac.
3. Ripple & noise are measured at 20MHz bandwidth with 0.1 µf ceramic & 10 µf electrolytic capacitors on the output.
4. See derating curves
th
conditions/description
output power derated from 85-90 V ac
AC input of 110 V ac
AC input of 220 V ac
AC input of 110 V ac, full load, cold start
AC input of 220 V ac, full load, cold start
built-in, non-user serviceable
conditions/description
see table above, typical values measured
at 115 V ac, full load
at 115 V ac, full load
current limiting starts at 105% of the rated output current and recovers automatically
protected, long-term short circuit may reduce reliability
conditions/description
The two earth ground pads are connected to input earth ground.
Ave. Tualatin, Oregon 97062
output voltage
(V dc)
3.3
12
15
24
48
5
output current
phone
phone 503.612.2300 fax
6.66
5.33
3.33
1.66
(A)
10
10
DESCRIPTION: switching power supply
4
total regulation
-0.05
min
min
-10
85
47
8
(%)
±5
±5
±5
±5
±5
±5
fax 503.612.2383
1500
nom
nom
800
1,2
ripple & noise
+0.05
max
max
(mVp-pmax.)
264
63
25
50
+5
120
120
120
150
240
480
units
units
%/°C
V ac
www.v-infinity.com
mA
mA
mS
Hz
%
A
A
3
page
date
rev.
page
date
efficiency
02/2010
1 of 4
(%)
75
76
85
86
87
89

Related parts for VOF-80

VOF-80 Summary of contents

Page 1

... PART NUMBER: VOF-80 features • no-load power consumption < 0.5W • universal input 85~264 V ac • over current, over voltage protected • industry standard footprint • efficiency up to 89% • safety approved to CB, TUV, CE, UL/cUL • conducted EMI meets EN55022 class B and FCC class B ...

Page 2

... PART NUMBER: VOF-80 GENERAL AND SAFETY parameter conditions/description switching frequency operating temp. storage temp. operating humidity non-condensing storage humidity non-condensing operating altitude storage altitude leakage current per EN60950, at 264 V ac isolation voltage primary to secondary (for 1 minute) primary to transformer core primary to ground ...

Page 3

... PART NUMBER: VOF-80 MECHANICAL parameter conditions/description dimensions 4” (102 mm) x 2” (51 mm) x 1.28” (32.6 mm) weight 0.2 Kg cooling method free air convection or forced air (see derating curves below) MATING CONNECTORS parameter conditions/description ac input (CN1) mates with Molex housing 09-50-7031 with Molex 2878 series crimp contact ...

Page 4

... CRITICAL DIMENSIONS FOR INSPECTION TOLERANCE: ±1.0mm 20050 SW 112th Ave. Tualatin, OR 97062 Phone: 503-612-2300 800-275-4899 Fax: 503-612-2383 CN1 Website: www.cui.com TITLE pin N VOF-80 MECHANICAL DRAWING PART NO. VOF-80-mech CN2 APPROVED BY: DRAWN BY: ZRJ - DATE 9/15/2009 4/1/2010 RoHS REV: ...