MAX1361EUB Maxim Integrated, MAX1361EUB Datasheet - Page 5

no-image

MAX1361EUB

Manufacturer Part Number
MAX1361EUB
Description
Analog to Digital Converters - ADC
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX1361EUB

Number Of Channels
4/2
Architecture
SAR
Conversion Rate
150 KSPs
Resolution
10 bit
Input Type
Single-Ended/Differential
Snr
Yes
Interface Type
Serial (2-Wire, I2C, SMBus)
Operating Supply Voltage
2.7 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Package / Case
uMAX
Maximum Power Dissipation
689.7 mW
Minimum Operating Temperature
- 40 C
Number Of Converters
1
Voltage Reference
Internal 4.096 V or External

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX1361EUB
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX1361EUB+
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX1361EUB+T
Manufacturer:
MICREL
Quantity:
1 778
ELECTRICAL CHARACTERISTICS (continued)
(V
0.1µF, f
TIMING CHARACTERISTICS FOR FAST MODE (Figures 1a, 2)
Serial Clock Frequency
Bus Free Time Between a
STOP (P) and a
START (S) Condition
Hold Time for START (S)
Condition
Low Period of the SCL Clock
High Period of the SCL Clock
Setup Time for a Repeated
START Condition (Sr)
Data Hold Time
Data Setup Time
Rise Time of Both SDA and SCL
Signals, Receiving
Fall Time of SDA Transmitting
Setup Time for STOP (P)
Condition
Capacitive Load for Each Bus
Line
Pulse Width of Spike Suppressed
TIMING CHARACTERISTICS FOR HIGH-SPEED MODE (C
Serial-Clock Frequency
Hold Time, Repeated START
Condition (Sr)
Low Period of the SCL Clock
High Period of the SCL Clock
Setup Time for a Repeated
START Condition (Sr)
Data Hold Time
Data Setup Time
Rise Time of SCL Signal
Rise Time of SCL Signal After
Acknowledge Bit
Fall Time of SCL Signal
Rise Time of SDA Signal
Fall Time of SDA Signal
Setup Time for STOP (P)
Condition
Capacitive Load for Each Bus
Pulse Width of Spike Suppressed
4-Channel, 10-Bit, System Monitor with Programmable
DD
= 2.7V to 3.6V (MAX1361), V
SCL
PARAMETER
= 1.7MHz, T
_______________________________________________________________________________________
A
= T
MIN
to T
Trip Window and SMBus Alert Response
DD
MAX
SYMBOL
t
t
t
t
t
t
t
t
t
t
HD, STA
HD, DAT
SU, STO
HD, STA
HD, DAT
SU, STO
SU, STA
SU, DAT
SU, STA
SU, DAT
= 4.5V to 5.5V (MAX1362), V
f
t
t
t
t
t
t
f
t
HIGH
SCLH
HIGH
t
RCL1
t
t
LOW
LOW
RDA
BUF
C
RCL
FDA
C
, unless otherwise noted. Typical values are at T
SCL
FCL
t
t
R
F
B
B
Measured from 0.3V
Measured from 0.3V
(Note 13)
(Note 13)
(Note 14)
Measured from 0.3V
Measured from 0.3V
Measured from 0.3V
Measured from 0.3V
Measured from 0.3V
B
= 400pF, Figures 1a, 2) (Note 12)
CONDITIONS
REF
DD
DD
DD
DD
DD
DD
DD
to 0.7V
to 0.7V
to 0.7V
to 0.7V
to 0.7V
to 0.7V
to 0.7V
= 2.048V (MAX1361), V
DD
DD
DD
DD
DD
DD
DD
A
= +25°C.)
MIN
100
160
320
120
160
160
1.3
0.6
1.3
0.6
0.6
0.6
REF
10
20
20
20
20
20
0
0
0
0
0
= 4.096V (MAX1362), C
TYP
MAX
400
900
300
300
400
150
160
160
160
400
1.7
50
80
80
10
UNITS
MHz
kHz
pF
pF
μs
μs
μs
μs
μs
ns
ns
ns
ns
μs
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
REF
5
=

Related parts for MAX1361EUB