MAX198BEWI-T Maxim Integrated, MAX198BEWI-T Datasheet
MAX198BEWI-T
Specifications of MAX198BEWI-T
Related parts for MAX198BEWI-T
MAX198BEWI-T Summary of contents
Page 1
... Robotics Data-Acquisition Systems Automatic Testing Systems Medical Instruments Telecommunications Functional Diagram appears at end of data sheet. ________________________________________________________________ Maxim Integrated Products Call toll free 1-800-722-8266 for free samples or literature. with 12-Bit Bus Interface ____________________________Features 12-Bit Resolution, 1/2LSB Linearity Single +5V Supply Operation Software-Selectable Input Ranges: ± ...
Page 2
Multirange, Single +5V, 12-Bit DAS with 12-Bit Bus Interface ABSOLUTE MAXIMUM RATINGS V to AGND............................................................-0.3V to +7V DD AGND to DGND.....................................................-0.3V to +0.3V REF to AGND..............................................-0. REFADJ to AGND.......................................-0. Digital Inputs to DGND...............................-0. Digital ...
Page 3
Multirange, Single +5V, 12-Bit DAS ELECTRICAL CHARACTERISTICS (continued ±5%; unipolar/bipolar range; external reference mode with 50% duty cycle unless otherwise noted. Typical values are MIN MAX ...
Page 4
Multirange, Single +5V, 12-Bit DAS with 12-Bit Bus Interface ELECTRICAL CHARACTERISTICS (continued ±5%; unipolar/bipolar range; external reference mode with 50% duty cycle unless otherwise noted. Typical values are at ...
Page 5
Multirange, Single +5V, 12-Bit DAS ELECTRICAL CHARACTERISTICS (continued ±5%; unipolar/bipolar range; external reference mode with 50% duty cycle unless otherwise noted. Typical values are MIN MAX ...
Page 6
Multirange, Single +5V, 12-Bit DAS with 12-Bit Bus Interface __________________________________________Typical Operating Characteristics (T = +25°C, unless otherwise noted.) A INTEGRAL NONLINEARITY vs. DIGITAL CODE 0.250 0.200 0.150 0.100 0.050 0 -0.050 -0.100 -0.150 0 1000 2000 3000 4000 DIGITAL CODE ...
Page 7
Multirange, Single +5V, 12-Bit DAS ______________________________________________________________Pin Description PIN NAME Clock Input. In external clock mode, drive CLK with a TTL/CMOS-compatible clock. In internal clock mode, 1 CLK place a capacitor (C with C = 100pF. CLK 2 CS Chip Select, ...
Page 8
Multirange, Single +5V, 12-Bit DAS with 12-Bit Bus Interface Acquisition time is calculated as follows: For REF For / ...
Page 9
Multirange, Single +5V, 12-Bit DAS Table 2. Control-Byte Format D7 (MSB PD1 PD0 ACQMOD BIT NAME 7, 6 PD1, PD0 These two bits select the clock and power-down modes (Table 4). 5 ACQMOD 0 = internally controlled acquisition ...
Page 10
Multirange, Single +5V, 12-Bit DAS with 12-Bit Bus Interface The control byte is latched into the device, on pins D7–D0, during a write cycle. Table 2 shows the control- byte format. Output Data Format The output data format is binary ...
Page 11
Multirange, Single +5V, 12-Bit DAS CSWS CSHW CONTROL D7–D0 BYTE ACQMOD = "1" INT RD DOUT Figure 6. Conversion Timing Using External Acquisition Mode The MAX196/MAX198 operate with ...
Page 12
Multirange, Single +5V, 12-Bit DAS with 12-Bit Bus Interface ACQUISITION STARTS CLK t CWS WR ACQMOD = "0" t ACQUISITION STARTS CWH CLK WR ACQMOD = "0" Figure 8a. External Clock and WR Timing (Internal Acquisition Mode) ACQUISITION STARTS CLK ...
Page 13
Multirange, Single +5V, 12-Bit DAS __________Applications Information Power-On Reset At power-up, the internal power-on reset circuitry sets INT high and puts the device in normal operation/exter- nal clock mode. This state is selected to keep the inter- nal clock from ...
Page 14
Multirange, Single +5V, 12-Bit DAS with 12-Bit Bus Interface results may be read. Input overvoltage protection is active in all power-down modes. The device returns to normal operation on the first WR falling edge during write operation. Choosing Power-Down Modes ...
Page 15
Multirange, Single +5V, 12-Bit DAS Layout, Grounding, and Bypassing Careful printed circuit board layout is essential for best system performance. For best performance, use a ground plane. To reduce crosstalk and noise injection, keep analog and digital signals separate. Digital ...
Page 16
... Dice* MAX198AENI -40°C to +85°C 28 Narrow Plastic DIP MAX198BENI -40°C to +85°C 28 Narrow Plastic DIP MAX198AEWI -40°C to +85°C 28 Wide SO MAX198BEWI -40°C to +85°C 28 Wide SO MAX198AEAI -40°C to +85°C 28 SSOP MAX198BEAI -40°C to +85°C 28 SSOP MAX198AMYI -55°C to +125°C ...