GLS85LP1008B-M-C-LFTE (rev. CB1) Greenliant, GLS85LP1008B-M-C-LFTE (rev. CB1) Datasheet - Page 18

no-image

GLS85LP1008B-M-C-LFTE (rev. CB1)

Manufacturer Part Number
GLS85LP1008B-M-C-LFTE (rev. CB1)
Description
Flash 8G MLC, NAND MLC 3.3V Comm
Manufacturer
Greenliant

Specifications of GLS85LP1008B-M-C-LFTE (rev. CB1)

Product Category
Flash
Rohs
yes
Advance Information
©2010 Greenliant Systems, Ltd.
Word 67: Minimum PIO Transfer Cycle Time Without Flow Control
This field defines, in nanoseconds, the minimum cycle time that, if used by the host, the device
guarantees data integrity during the transfer without utilization of IORDY flow control. If this field is
supported, Bit 1 of word 53 shall be set to one.NANDrive supports PIO Mode-4, so this field is set
to 120ns.
Note: NANDrive is capable of supporting PIO Mode-6 cycle time of 80ns (0050H). Contact Green-
Word 68: Minimum PIO Transfer Cycle Time With IORDY
This field defines, in nanoseconds, the minimum cycle time that the device supports while perform-
ing data transfers while utilizing IORDY flow control. If this field is supported, Bit 1 of word 53 shall
be set to one. NANDrive supports PIO Mode-4, so this field is set to 120ns.
Note: NANDrive is capable of supporting PIO Mode-6 cycle time of 80ns (0050H). Contact Green-
Word 80: Major Version Number
If not 0000H or FFFFH, the device claims compliance with the major version(s) as indicated by bits
[6:1] being set to one. Since ATA standards maintain downward compatibility, a device may set
more than one bit. GLS85LP1008B supports ATA-1 to ATA-7.
Word 81: Minor Version Number
If an implementer claims that the revision of the standard they used to guide their implementation
does not need to be reported or if the implementation was based upon a standard prior to the ATA-
3 standard, word 81 should be 0000H or FFFFH.
A value of 0021H reported in word 81 indicates ATA-7 T13/1532D volume 1, revision 4b guided the
implementation.
Words 82-84: Features/command sets supported
Words 82, 83, and 84 indicate the features and command sets supported. A value of 706BH is
reported.
Word 82
Bit
15
14
13
12
11
10
9
8
7
6
5
4
liant sales for more details.
liant sales for more details.
Function
0: Obsolete
1: NOP command is supported
1: Read Buffer command is supported
1: Write Buffer command is supported
0: Obsolete
0: Host Protected Area feature set is not supported
0: Device Reset command is not supported
0: Service interrupt is not supported
0: Release interrupt is not supported
1: Look-ahead is supported
1: Write cache is supported
0: Packet Command feature set is not supported
18
8 GByte NANDrive
GLS85LP1008B
S71421-02-000
05/10

Related parts for GLS85LP1008B-M-C-LFTE (rev. CB1)