NHD-5.0-800480TF-20 Controller Board Newhaven Display, NHD-5.0-800480TF-20 Controller Board Datasheet
NHD-5.0-800480TF-20 Controller Board
Specifications of NHD-5.0-800480TF-20 Controller Board
Related parts for NHD-5.0-800480TF-20 Controller Board
NHD-5.0-800480TF-20 Controller Board Summary of contents
Page 1
... NHD‐5.0‐800480TF‐20 Controller Board TFT Controller Evaluation Board NHD‐ Newhaven Display 5.0‐ 5.0” Diagonal 800480‐ 800xRGBx480 pixels TF‐ Model 20‐ ...
Page 2
... Functions and Features • To use for testing, evaluating, or in final production with NHD‐5.0‐800480TF‐A displays. ...
Page 3
... Mechanical Drawing NHD‐5.0‐800480TF Test Board ...
Page 4
Note: J2 has a 20‐POS FFC connector assembled, pins 21, 22 are not connected. Pin Description: J1 (SSD1963 output to display panel) Pin No. Symbol External Connection 1 LED‐ LED Power Supply Ground for Backlight 2 LED+ LED Power Supply Backlight Power Supply (20mA @ ~23.1V) 3 GND Power Supply 4 VDD Power Supply 5‐12 [R0‐R7] MPU 13‐20 [G0‐G7] MPU 21‐28 [B0‐B7] MPU 29 GND Power Supply 30 CLKIN MPU 31 STBYB MPU 32 ...
Page 5
Electrical Characteristics Item Operating Temperature Range Storage Temperature Range Supply Voltage Input High Voltage Input Low Voltage Supply Current Power Consumption Controller Information Built‐in SSD1963 For specific timing and color information, please download specification at http://www.newhavendisplay.com/app_notes/SSD1963.pdf Symbol Condition Min. Top Absolute Max ...
Page 6
8080 Mode Timing: ...
Page 7
Quality Information Test Item High Temperature storage storage temperature for a long time. Low Temperature storage Endurance test applying the low storage temperature for a long time. High Temperature Endurance test applying the electric stress Operation (voltage & current) and the high thermal stress for a long time. Low Temperature Endurance test applying the electric stress Operation (voltage & current) and the low thermal stress for a long time. High Temperature / Endurance test applying the electric stress Humidity Operation (voltage & current) and the high thermal with high humidity stress for a long time. Thermal Shock resistance Endurance test applying the electric stress (voltage & current) during a cycle of low and high thermal stress. Vibration test Endurance test applying vibration to simulate transportation and use. Static electricity test Endurance test applying electric static discharge. Note 1: No condensation to be observed. Note 2: Conducted after 4 hours of storage at 25 Note 3: Test performed on product itself, not inside a container. Precautions for using LCDs/LCMs See Precautions at www.newhavendisplay.com/specs/precautions.pdf ...