Datasheet

Specifications of MAX3317EEUP-T

Data Rate
460 Kbps
Operating Supply Voltage
2.25 V to 3 V
Supply Current
300 uA
Operating Temperature Range
0 C to + 70 C
Mounting Style
SMD/SMT
Number Of Drivers
2
Number Of I/os
2 / 2
Number Of Receivers
2
Propagation Delay Time Ns
0.175 us
down is typically 30µs, as shown in Figure 2. Connect
SHDN to V
has no effect on R_OUT.
Maxim’s AutoShutdown Plus feature on the MAX3318E/
MAX3319E allows the supply current to fall to 1µA.
These devices will enter the AutoShutdown Plus mode if
FORCEOFF is high, FORCEON is low, and they do not
±15kV ESD-Protected, 2.5V, 1µA, 460kbps,
RS-232 Compatible Transceivers
Table 1. Output Control Truth Table (MAX3318E/MAX3319E)
X = Don’t care
* INVALID connected to FORCEON
** INVALID connected to FORCEON and FORCEOFF
Table 2. Shutdown and Enable Control
Truth Table (MAX3317E)
8
Shutdown (Forced
Off)
Normal Operation
(Forced On)
Normal Operation
(AutoShutdown Plus)
Shutdown
(AutoShutdown Plus)
Normal Operation
Normal Operation
Shutdown
Normal Operation
(AutoShutdown)
Shutdown
(AutoShutdown)
_______________________________________________________________________________________
OPERATION
SHDN
STATUS
0
0
1
1
CC
if the shutdown mode is not used; SHDN
EN
0
1
0
1
AutoShutdown Plus Mode
FORCEON
INVALID**
INVALID**
INVALID*
INVALID*
INVALID*
MAX3318E/MAX3319E
X
1
0
0
T_OUT
High-Z
High-Z
Active
Active
FORCEOFF
INVALID**
INVALID**
0
1
1
1
1
1
1
R_OUT
High-Z
High-Z
Active
Active
VALID RECEIVER
LEVEL
Yes
Yes
No
No
sense a valid signal transition on any receiver or trans-
mitter input for 30 seconds. This may occur if the RS-232
cable is disconnected or if the peripheral transmitters
are turned off, and the UART driving the transmitter
inputs is inactive. The system turns on again when a
valid transition is applied to any RS-232 receiver or
transmitter input. As a result, the system saves power
without changes to the existing BIOS or operating system.
Figure 4a depicts valid and invalid RS-232 receiver volt-
age levels. INVALID indicates the receiver input’s condi-
tion and is independent of FORCEON and FORCEOFF
states. Figure 3 and Table 1 summarize the operating
modes of the MAX3318E/MAX3319E. FORCEON and
FORCEOFF override AutoShutdown Plus circuitry. When
neither control is asserted, the IC selects between these
states automatically based on the last receiver or trans-
mitter edge received.
When shut down, the device’s charge pumps turn off,
V+ is pulled to V
outputs are high impedance, and READY is driven low.
The time required to exit shutdown is typically 30µs
(Figure 2).
X
X
X
X
X
TRANSMITTER
RECEIVER OR
EDGE WITHIN
CC
30s
Yes
Yes
No
No
X
X
X
X
X
, V- is pulled to ground, the transmitter
T_OUT
High-Z
High-Z
High-Z
High-Z
Active
Active
Active
Active
Active
R_OUT
Active
Active
Active
Active
Active
Active
Active
Active
Active

Related parts for MAX3317EEUP-T