NM485D Murata Power Solutions, NM485D Datasheet

no-image

NM485D

Manufacturer Part Number
NM485D
Description
RS-485 Interface IC TX-RX EIA-485
Manufacturer
Murata Power Solutions
Datasheet

Specifications of NM485D

Product Category
RS-485 Interface IC
Data Rate
1.25 Mbps
Operating Supply Voltage
5 V
Operating Temperature Range
0 C to + 60 C
Mounting Style
Through Hole
Package / Case
DIL-24
Function
Driver/Receiver
Maximum Operating Temperature
+ 60 C
Minimum Operating Temperature
0 C
Number Of Drivers
2
Number Of Receivers
2
Shutdown
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NM485D
Manufacturer:
MURATA
Quantity:
20 000
Part Number:
NM485DC
Manufacturer:
Murata Power Solutions Inc
Quantity:
135
FEATURES
DESCRIPTION
The NM485DC is an electrically isolated dual
differential driver and receiver designed for bal-
anced mulipoint bus transmission at rates up to
1.25Mbits per second. The device provides two
receive channels and two driver channels. The
two driver channels have an active high enable.
No external components are needed and a single
5V input supply powers all functions either side of
the isolation boundary. The driver outputs provide
limiting for positive and negative currents and
thermal shutdown protection from line fault condi-
tions on the transmission bus line. The receiver
outputs will always be high if the receiver inputs
are open. The isolation voltage between input and
output is 1000Vrms, the devices are supplied in a
low profile 24 pin DIL plastic package.
www.murata-ps.com
www.murata-ps.com/support
RoHS compliant
Single 5V supply
Thermal shutdown protection
EIA-485 and CCITT V.28 compatible
Dual differential driver and receiver
Driver tri-state outputs active high enable
Low Profile 24 pin DIL package style
1kVrms Isolation
www.murata-ps.com/rohs
For full details go to
 
All data taken at T
ELECTRICAL CHARACTERISTICS
ELECTRICAL CHARACTERISTICS
Parameter
Supply voltage, V
High level input voltage, V
Low level input voltage, V
Common mode output voltage, V
High level output current I
Low level output current, I
Common mode input voltage, V
Differential input voltage, V
High level output current, I
Low level output current, I
EACH RECEIVER ELECTRICAL CHARACTERISTICS
Parameter
High threshold differential input, V
Low threshold differential input, V
Input hysteresis, ΔV
High level output voltage, V
Low level output voltage, V
Line input current, I
Short circuit output current, I
Input resistance, R
RECEIVER SWITCHING CHARACTERISTICS
Parameter
Propagation delay time L to H, T
Propagation delay time H to L, T
RECEIVER FUNCTION TABLE
ISOLATION CHARACTERISTICS
Parameter
Isolation test voltage
ABSOLUTE MAXIMUM RATINGS
Supply voltage V
Input voltage D
Input voltage range, receiver A or B inputs
Receiver differential input voltage range
Output voltage range, driver
Power dissipation
Isolation capacitance
Isolation voltage (flash tested for 1 second)
Data transmission rate
Lead temperature 1.5mm from case for 10 seconds
A
=25°C, V
X
CC
ENABLE and D inputs
CC
Differential inputs A-B
I
with respect to pin 11
I
T
-0.2V<V
CC
V
=5V.
V
IL
ID
OH
OL
OL
ID
IH
OH
ID
OL
≤-0.2V
OH
≥0.2V
ID
OS
<+0.2V
IC
PLH
PHL
OC
TL
TH
Test conditions
D
Driver
Receiver
Test conditions
V
V
V
V
Other input at 0V, V
Other input at 0V, V
Test conditions
V
Conditions
Flash tested for 1 second
O
O
ID
ID
ID
X
=2.7V, I
=0.5V, I
=200mV, I
=200mV, I
=-1.5V to 1.5V, C
ENABLE and D inputs
Isolated Dual EIA-485 Driver and Receiver
O
O
=-0.4mA
=16mA
OH
OL
=25mA
=-5.0mA
I
I
=12V
=-12V
L
=15pF
ual
NM485DC Series
N
1000
Min.
4.75
Min.
Min.
Min.
-7.0
-0.2
2.8
2.7
12
High level
Undefined
Low level
KII_NM485DC.A05 Page 1 of 6
RX
OUT
Typ.
Typ.
Typ.
Typ.
5.0
-25V to +25V
-25V to +25V
-10V to +15V
50
70
72
1000Vrms
1.25Mbps
2000mW
300ºC
40pF
7V
7V
Max.
Max.
Max.
Max.
5.25
±12
±12
-5.0
-0.8
-60
-15
155
135
0.8
0.2
0.8
1.0
12
60
25
Units
Units
Units
Units
Vrms
mA
mA
mA
mA
mV
mA
mA
mA
ns
ns
V
V
V
V
V
V
V
V
V
V

Related parts for NM485D

NM485D Summary of contents

Page 1

... Low Profile 24 pin DIL package style „ 1kVrms Isolation DESCRIPTION The NM485DC is an electrically isolated dual differential driver and receiver designed for bal- anced mulipoint bus transmission at rates up to 1.25Mbits per second. The device provides two receive channels and two driver channels. The two driver channels have an active high enable ...

Page 2

... Max 120 145 70 145 150 300 80 120 Output Z Low level High level High impedance Min. Typ. Max -40 125 KII_NM485DC.A05 Page Units μA μ Units Units ºC ºC ...

Page 3

... The maximum number of drivers and receivers that may be placed on a single communication bus depends upon their loading characteristics, relative to the definition of a Unit Load (U.L.), transmission speed does not affect the unit load capability. As the NM485DC complies with the EIA-485 standard a maximum of 32 unit loads per line is recommended. A unit load usually consists of a driver-receiver pair, but not the line termination resistors. With only a 5V supply connected, the NM485DC receiver and differential outputs give levels greater than +2.7V and ± ...

Page 4

... LONWORKS data rate standard is 1.25Mbps. The resultant maximum system performance for the LONWORKS EIA-485 con- figuration is therefore 32 nodes at 1.25Mbps. The NM485D isolated serial interface devices supports this configuration, as well as any lower specified system. The EIA-485 standard defines the maximum line length as a function of data rate (in Mbps). This implies that the user must choose between the line length of the network and its maximum data transmission rate. The isolated interface has been used in previous confi ...

Page 5

... A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” For a part holding no specific agency approvals, such as the NM485DC series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier ...

Page 6

... All dimensions are in inches (mm) ±0.01 (0.25) TUBE OUTLINE DIMENSIONS All dimensions are in inches (mm) ±0.01 (0.25) This product is subject to the following and the Life and Safety Critical Application Sales Refer to: http://www.murata-ps.com/requirements/ Tube Quantity : 15 operating requirements Policy: © 2012 Murata Power Solutions, Inc. KII_NM485DC.A05 Page ...

Related keywords