MAX6847KARD7-T Maxim Integrated, MAX6847KARD7-T Datasheet
MAX6847KARD7-T
Specifications of MAX6847KARD7-T
Related parts for MAX6847KARD7-T
MAX6847KARD7-T Summary of contents
Page 1
... Portable Medical Devices Digital Cameras Pagers PDAs MP3 Players Electronic Toys ________________________________________________________________ Maxim Integrated Products For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at 1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com. ♦ User-Adjustable Thresholds for Monitoring Single-Cell Li+ or Multicell Alkaline/NiCd/NiMH Applications ♦ ...
Page 2
Low-Power, Adjustable Battery Monitors with Hysteresis and Integrated µP Reset ABSOLUTE MAXIMUM RATINGS GND ....................................................-0.3V to +6V Open-Drain LBO, LBOH, LBOL to GND .................-0.3V to +6V* Open-Drain RESET to GND ....................................-0.3V to +6V* Push-Pull ...
Page 3
Low-Power, Adjustable Battery Monitors with Hysteresis and Integrated µP Reset ELECTRICAL CHARACTERISTICS (continued 1.6V to 5.5V 1.2V to 5.5V PARAMETER SYMBOL LBO, LBOL, LBOH Output Open-Drain Leakage Current V Reset Threshold CC V ...
Page 4
Low-Power, Adjustable Battery Monitors with Hysteresis and Integrated µP Reset (V = 3.6V 3.3V, unless otherwise specified. Typical values are SUPPLY CURRENT vs. TEMPERATURE 3.3V 3. ...
Page 5
Low-Power, Adjustable Battery Monitors with Hysteresis and Integrated µP Reset (V = 3.6V 3.3V, unless otherwise specified. Typical values are NORMALIZED UPPER AND LOWER LBO TRIP VOLTAGES vs. TEMPERATURE 1.050 1.025 1.000 0.975 0.950 ...
Page 6
Low-Power, Adjustable Battery Monitors with Hysteresis and Integrated µP Reset PIN MAX6846/MAX6847 MAX6848/MAX6849 — — — 6 — 4 Detailed Description The MAX6846–MAX6849 family is available ...
Page 7
Low-Power, Adjustable Battery Monitors with Hysteresis and Integrated µP Reset V DD LTHIN LTH DETECT HTHIN HTH LBO TIMEOUT DETECT PERIOD 615mV V CC RESET V TH TIMEOUT DETECT PERIOD 1.23V MR Figure 1a. MAX6847 Functional Diagram Low-Battery Output The ...
Page 8
Low-Power, Adjustable Battery Monitors with Hysteresis and Integrated µP Reset V MONITORED V HTH TRIPHIGH V LTH TRIPLOW LBO V = HYSTERESIS HYST Figure 2. Single Low-Battery Output Timing V MONITORED (V +5%) HTH+ TRIPHIGH V HTH- TRIPHIGH (V +5%) ...
Page 9
Low-Power, Adjustable Battery Monitors with Hysteresis and Integrated µP Reset Many microprocessor-based products require manual reset capability, allowing the operator, a test technician, or external logic circuitry to initiate a reset while the monitored supplies remain above their reset thresholds. ...
Page 10
Low-Power, Adjustable Battery Monitors with Hysteresis and Integrated µP Reset 1) Choose a value for R , the sum of R1, R2, and TOTAL R3. Because the MAX6848/MAX6849 have very high input impedance, R can 500kΩ. TOTAL ...
Page 11
Low-Power, Adjustable Battery Monitors with Hysteresis and Integrated µP Reset OPEN-DRAIN PART RESET MAX6846 X MAX6847 — MAX6848 X MAX6849 — Standard Versions Table PART MAX6846KARD3 MAX6846KASD3 MAX6846KAWD3 MAX6846KAZD3 MAX6847KARD3 MAX6847KASD3 MAX6847KAWD3 MAX6847KAZD3 MAX6848KARD3 MAX6848KASD3 MAX6848KAWD3 MAX6848KAZD3 MAX6849KARD3 MAX6849KASD3 MAX6849KAWD3 ...
Page 12
... Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. 12 ____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 © 2005 Maxim Integrated Products SEE DETAIL "A" ...