MAX1906VEEE Maxim Integrated, MAX1906VEEE Datasheet - Page 9

no-image

MAX1906VEEE

Manufacturer Part Number
MAX1906VEEE
Description
Battery Management
Manufacturer
Maxim Integrated
Series
MAX1906r
Datasheet
Figure 6. Current Consumption of Chip in Different States
Figure 7. Timing Diagram for Test Mode
high and the DISCON pin is set to its high-impedance
state. After 130ms, the DRV pin is pulled low by the
MAX1906, exiting the test mode. The time period of
130ms has been chosen not to stress the three-terminal
protection fuse if an external MOSFET is used to blow the
fuse. The OUT pin is not affected by the test mode. See
the timing diagram for the test mode in Figure 7.
NOTE: ALL VALUES ARE TYPICAL.
_______________________________________________________________________________________
V
DISCON
V
V
V
V
I
SUP
DRV
TEST
I
B_P
SUP
DRV
300µA
0.8ms
50µs
0.8ms
Li+ Battery-Pack Protector with
3.2µA
2.56s
IF ALL CELLS ARE TESTED TO BE IN
OVERVOLTAGE CONDITION
130ms
STOP SAMPLING AND MONITOR ONLY
CELL UNDER MEASUREMENT
Entry into test mode is ignored if the MAX1906 has
detected an overvoltage condition and has activated
the 2.1s delay. Test mode remains disabled until the
MAX1906 exits the overvoltage condition. The
MAX1906 continues normal operation upon exit from
the test mode.
Integrated Fuse Driver
2.1s
4.8V
0.8ms
V
V
OV_TH
REL
9

Related parts for MAX1906VEEE