MAX16049ATN+T Maxim Integrated, MAX16049ATN+T Datasheet - Page 39

no-image

MAX16049ATN+T

Manufacturer Part Number
MAX16049ATN+T
Description
Supervisory Circuits 8Ch EEPROM Prob System Manager
Manufacturer
Maxim Integrated
Series
MAX16047, MAX16049r
Datasheet

Specifications of MAX16049ATN+T

Rohs
yes
The reset output, RESET, is asserted during power-
up/power-down and deasserts following the reset time-
out period once the power-up sequence is complete.
The power-up sequence is complete when any MON_
inputs assigned to Slot 12 exceed their undervoltage
thresholds. If no MON_ inputs are assigned to Slot 12,
the power-up sequence is complete after the slot
sequence delay is expired.
Table 20. EEPROM Fault Log Operation Period
Table 21. RESET Configuration and Dependencies
System Managers with Nonvolatile Fault Registers
REGISTER r47h[1:0]
FAULT CONTROL
REGISTER/
ADDRESS
EEPROM
19h
00
01
10
11
12-Channel/8-Channel EEPROM-Programmable
______________________________________________________________________________________
BIT RANGE
[1:0]
[6:4]
Failed lines and ADC values saved
Failed lines saved
ADC values saved
No information saved
[2]
[3]
[7]
RESET OUTPUT CONFIGURATION
00 = RESET is asserted if at least one of the selected inputs exceeds its undervoltage
threshold
01 = RESET is asserted if at least one of the selected inputs exceeds its early warning
threshold
10 = RESET is asserted if at least one of the selected inputs exceeds its overvoltage threshold
11 = RESET is asserted if any of the selected inputs exceeds undervoltage or overvoltage
thresholds
0 = RESET is an active-low output
1 = RESET is an active-high output
0 = RESET is a open-drain output
1 = RESET is an push-pull output
RESET TIMEOUT
000 = 25µs
001 = 2ms
010 = 25ms
011 = 100ms
100 = 200ms
101 = 400ms
110 = 800ms
111 = 1600ms
Reserved
DESCRIPTION
RESET
RESET is a configurable output that monitors selected
MON_ voltages during normal operation. RESET also
depends on any monitoring input that has one or more
critical fault enable bits set. Use r19h[1:0] to configure
RESET to assert on an overvoltage fault, undervoltage
fault, or both. Use r19h[3:2] to configure RESET as an
active-high/active-low push-pull/open-drain output. If
desired, configure GPIO4 as a manual reset input, MR,
and pull MR low to assert RESET. RESET includes a
programmable timeout. See Table 21 for RESET depen-
dencies and configuration registers.
DESCRIPTION
MINIMUM REQUIRED SHUTDOWN PERIOD
(ms)
204
168
N/A
60
39

Related parts for MAX16049ATN+T