MAX6841GUKD2+T Maxim Integrated, MAX6841GUKD2+T Datasheet - Page 2

no-image

MAX6841GUKD2+T

Manufacturer Part Number
MAX6841GUKD2+T
Description
Supervisory Circuits
Manufacturer
Maxim Integrated
Series
MAX6841, MAX6842, MAX6843, MAX6844, MAX6845r
Datasheet

Specifications of MAX6841GUKD2+T

Number Of Voltages Monitored
1
Monitored Voltage
0.9 V to 1.5 V
Undervoltage Threshold
1.08 V
Overvoltage Threshold
1.14 V
Output Type
Active High, Active Low, Push-Pull
Manual Reset
Resettable
Watchdog
No Watchdog
Battery Backup Switching
No Backup
Power-up Reset Delay (typ)
40 ms
Supply Voltage - Max
1.8 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
SOT-23
Chip Enable Signals
No
Maximum Power Dissipation
571 mW
Minimum Operating Temperature
- 40 C
Power Fail Detection
No
Supply Current (typ)
8.1 uA
Supply Voltage - Min
0.75 V
IN, FB,
OUT to AGND, LX to PGND
AGND to PGND . . . . . . . . . . . . . . . . . . . . . . . . . .-0.3V to +0.3V
OUT Short Circuit to GND . . . . . . . . . . . . . . . . . . . . . . . . . . .10s
Continuous Power Dissipation (TA = +70°C)
Low-Voltage, 400mA Step-Down
DC-DC Converters in SOT23
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
(V
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
2
Input Voltage Range
Startup Voltage
UVLO Threshold
UVLO Hysteresis
Quiescent Supply Current
Quiescent Supply Current
Dropout
Shutdown Supply Current
Output Voltage Accuracy
(MAX1921)
OUT BIAS Current
Output Voltage Range (MAX1920)
FB Feedback Threshold
(MAX1920)
FB Feedback Hysteresis
(MAX1920)
FB Bias Current (MAX1920)
Load Regulation
Line Regulation
SHDN Input Voltage High
SHDN Input Voltage Low
SHDN Leakage Current
High-Side Current Limit
IN
6-Pin SOT23-6 (derate 8.7mW/°C above +70°C) . . . .695mW
6-Pin TDFN (derate 18.2mW/°C above +70°C) . . .1454.5mW
_______________________________________________________________________________________
= 3.6V, SHDN = IN, T
SHDN to AGND . . . . . . . . . . . . . . . . . . . . .-0.3V to +6V
PARAMETER
A
= 0°C to +85°C. Typical parameters are at T
. . . . . . . . . . . .-0.3V to (IN + 0.3V)
SYMBOL
I
UVLO
I
V
SHDN
SHDN
I
I
V
LIMP
V
OUT
V
I
V
I
I
HYS
FB
IN
IN
FB
IN
IH
IL
I(LX) < 400mA
I(LX) < 200mA
(MAX1921EUT15, MAX1921EUT18)
V
V
No switching, no load
SHDN = IN, OUT/FB = 0
SHDN = GND
I
I
I
SHDN = 0
OUT at regulation voltage
Figure 4, IN = 4.5V
T
T
FB = 1.5V
I
V
SHDN = GND or IN
OUT
OUT
OUT
OUT
A
A
IN
IN
IN
= 25°C
= -40°C to +85°C
rising
falling
= 2.5V to 5.5V
= 0, T
= 0 to 400mA, T
= 0 to 200mA, T
= 0 to 400mA
A
= +25°C
CONDITIONS
Operating Temperature Range . . . . . . . . . . . . . .-40°C to +85°C
Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . .+150°C
Storage Temperature . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Lead Temperature (soldering 10s) . . . . . . . . . . . . . . . . .+300°C
A
A
= -40°C to +85°C
= -40°C to +85°C
A
= +25°C, unless otherwise noted.) (Note 1)
1.220
1.210
1.231
1.50
MIN
1.25
-1.5
525
2.0
2.5
1.6
-3
-3
0.005
0.001
TYP
1.85
1.65
1.25
1.25
0.01
200
220
730
0.1
0.2
50
8
5
1.269
1.000
1.280
1.280
MAX
1.95
+1.5
4.00
0.20
300
950
5.5
2.0
4.0
0.4
2.5
70
+3
+3
16
1
UNITS
%/mA
%/V
mA
mV
mV
µA
µA
µA
µA
µA
µA
%
V
V
V
V
V
V
V