MAX6746KA46+T Maxim Integrated, MAX6746KA46+T Datasheet - Page 13

no-image

MAX6746KA46+T

Manufacturer Part Number
MAX6746KA46+T
Description
Supervisory Circuits
Manufacturer
Maxim Integrated
Series
MAX6746, MAX6747, MAX6748, MAX6749, MAX6750, MAX6751, MAX6752, MAX6753r
Datasheet

Specifications of MAX6746KA46+T

Number Of Voltages Monitored
1
Monitored Voltage
1.575 V to 5 V
Undervoltage Threshold
4.533 V
Overvoltage Threshold
4.718 V
Output Type
Active Low, Push-Pull
Manual Reset
Resettable
Watchdog
Watchdog
Battery Backup Switching
No Backup
Power-up Reset Delay (typ)
9.487 ms
Supply Voltage - Max
5.5 V
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Package / Case
SOT-23
Chip Enable Signals
No
Maximum Power Dissipation
714 mW
Minimum Operating Temperature
- 40 C
Power Fail Detection
No
Supply Current (typ)
5 uA
Supply Voltage - Min
1 V
The MAX5984 is a single-port, PSE power controller
designed for use in IEEE 802.3af/IEEE 802.3at-compliant
PSE. This device provides PD discovery, classification,
current limit, and DC and AC load-disconnect detec-
tions. The MAX5984 operates automatically without the
need for any software programming and features an inte-
grated power MOSFET and sense resistor. The device
also supports new Class 5 and 2-event classification
for detection and classification of high-power PDs. The
MAX5984 provides up to 40W to a single port (Class 5
enabled) and still provides high-capacitance detection
for legacy PDs.
MIDSPAN
LEGACY
AGND
LED
V
EN
EE
Single-Port, 40W, IEEE 802.3af/802.3at PSE
BIAS AND
MONITOR
REGISTER FILE
ANALOG
SUPPLY
______________________________________________________________________________________
Detailed Description
CENTRAL LOGIC
UNIT (CLU)
INTERNAL
SUPPLIES
VOLTAGE
REFERENCES
CURRENT
REFERENCES
2-EVENT/PWMEN/LSCEN
Controller with Integrated MOSFET
MACHINE (SM)
PORT STATE
OSC STATUS
MONITOR
2-EVENT/PWMEN/LSCEN
OSC
AC DISCONNECT
SIGNAL (ACD)
GENERATOR
TRIANGLE
WAVE
MAX5984
The MAX5984 provides input UVLO, input overvoltage
lockout, overtemperature detection, output voltage slew-
rate limit during startup, and LED status indication.
The MAX5984 is reset by any of the following conditions:
1) Power-up. Reset condition is cleared once V
2) Hardware reset. Reset occurs once the EN input is
3) Thermal shutdown. The device enters thermal shut-
CLASSIFICATION
DETECTION AND
CURRENT-LIMIT
above the UVLO threshold.
driven low (> 40µs typ) any time after power-up. The
device exits the reset condition once the EN input is
driven high again.
down at +150NC. The device exits thermal shutdown
and is reset once the temperature drops below 130NC.
PROBING AND
CONTROL
VOLTAGE
CONTROL
THRESHOLD
SETTINGS
AC DETECTOR
A = 1
ACD
REFERENCE
CURRENT
OVERCURRENT, AND OPEN-
CLASS 5 ENABLE/DISABLE,
AND FOLDBACK CONTROL
CURRENT LIMIT CONTROL
OVERCURRENT AND
CIRCUIT SENSING,
9-BIT ADC
CURRENT LIMIT,
AC DISCONNECT
ILIM1
CURRENT SENSING
DRIVE
GATE
ENABLE
Simplified Diagram
ILIM2
VOLTAGE
SENSING
FOLDBACK
CONTROL
INTERNAL
INTERNAL
MOSFET
R
SENSE
AGND
EE
Reset
DET
OUTP
OUT
rises
13