MAX708TEUA+ Maxim Integrated, MAX708TEUA+ Datasheet - Page 8

no-image

MAX708TEUA+

Manufacturer Part Number
MAX708TEUA+
Description
Supervisory Circuits +3V Voltage Monitoring Low-Cost P Supervisory Circuits
Manufacturer
Maxim Integrated
Series
MAX706AP, MAX706AR, MAX706AS, MAX706AT, MAX706P, MAX706R, MAX706S, MAX706T, MAX708R, MAX708S, MAX708Tr
Datasheet

Specifications of MAX708TEUA+

Number Of Voltages Monitored
1
Monitored Voltage
4.4 V
Undervoltage Threshold
3 V
Overvoltage Threshold
3.15 V
Output Type
Active High, Active Low, Push-Pull
Manual Reset
Resettable
Watchdog
No Watchdog
Battery Backup Switching
No Backup
Power-up Reset Delay (typ)
280 ms
Supply Voltage - Max
5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
uSOP
Chip Enable Signals
No
Maximum Power Dissipation
362 mW
Minimum Operating Temperature
- 40 C
Power Fail Detection
Yes
Supply Current (typ)
350 uA
Supply Voltage - Min
1 V
Dual/Triple Ultra-Low-Voltage SOT23 µP
Supervisory Circuits
8
MAX6715/
MAX6716
_______________________________________________________________________________________
MAX6717/
MAX6718
MAX6719/
MAX6720
5
MAX6721/
MAX6722
5
PIN
MAX6723/
MAX6724
3
5
MAX6725/
MAX6726
3
7
MAX6727
3
7
Pin Description (continued)
MAX6728/
MAX6729
3
7
NAME
RSTIN
WDI
PFI
Watchdog Input. If WDI
remains high or low for
longer than the watchdog
timeout period, the
internal watchdog timer
runs out and the reset
output asserts for the
reset timeout period. The
internal watchdog timer
clears whenever a reset
is asserted or WDI sees a
rising or falling edge. The
watchdog has a long
timeout period (35s min)
after each reset event
and a short timeout
period (1.12s min) after
the first valid WDI
transition.
Undervoltage Reset
Comparator Input. High-
impedance input for
adjustable reset monitor.
The reset output is
asserted when RSTIN falls
below the 0.626V internal
reference voltage. Set the
monitored voltage reset
threshold with an external
resistor-divider network.
Connect RSTIN to V
V
Power-Fail Voltage
Monitor Input. High-
impedance input for
internal power-fail monitor
comparator. Connect PFI
to an external resistor-
divider network to set the
power-fail threshold
voltage (0.626V typical
internal reference
voltage). Connect to
GND, V
not used.
CC
2 if not used.
FUNCTION
CC
1, or V
CC
2 if
CC
1 or

Related parts for MAX708TEUA+