24AA08-I/MS Microchip Technology, 24AA08-I/MS Datasheet - Page 6

IC EEPROM 8KBIT 400KHZ 8MSOP

24AA08-I/MS

Manufacturer Part Number
24AA08-I/MS
Description
IC EEPROM 8KBIT 400KHZ 8MSOP
Manufacturer
Microchip Technology
Datasheets

Specifications of 24AA08-I/MS

Memory Size
8K (4 x 256 x 8)
Format - Memory
EEPROMs - Serial
Memory Type
EEPROM
Speed
100kHz, 400kHz
Interface
I²C, 2-Wire Serial
Voltage - Supply
1.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Package / Case
8-MSOP, Micro8™, 8-uMAX, 8-uSOP,
Clock Frequency
400kHz
Supply Voltage Range
1.7V To 5.5V
Memory Case Style
MSOP
No. Of Pins
8
Operating Temperature Range
-40°C To +85°C
Svhc
No SVHC (15-Dec-2010)
Package /
RoHS Compliant
Memory Configuration
4 BLK (256 X 8)
Interface Type
I2C, Serial, 2-Wire
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
24AA08I/MS
24AA08/24LC08B
3.6
A control byte is the first byte received following the
Start condition from the master device (Figure 3-2).
The control byte consists of a four-bit control code. For
the 24XX08, this is set as ‘
write operations. The next three bits of the control byte
are the block-select bits (B2, B1, B0). B2 is a “don’t
care” for the 24XX08. They are used by the master
device to select which of the four 256 word-blocks of
memory are to be accessed. These bits are in effect the
three Most Significant bits of the word address.
The last bit of the control byte defines the operation to
be performed. When set to ‘
selected. When set to ‘
Following the Start condition, the 24XX08 monitors the
SDA bus, checking the device type identifier being
transmitted and, upon receiving a ‘
slave device outputs an Acknowledge signal on the
SDA line. Depending on the state of the R/W bit, the
24XX08 will select a read or write operation.
DS21710G-page 6
Operation
Read
Write
Device Addressing
Control
1010
1010
Code
0
’ a write operation is selected.
1010’
Block Address
Block Address
Block Select
1
’ a read operation is
binary for read and
1010’
code, the
R/W
1
0
FIGURE 3-2:
Start Bit
x = “don’t care”
S
1
Control Code
0
Slave Address
1
CONTROL BYTE
ALLOCATION
0
© 2007 Microchip Technology Inc.
x
Select
Block
Bits
B1 B0 R/W ACK
Acknowledge Bit
Read/Write Bit

Related parts for 24AA08-I/MS