CAT812LEUS-T Catalyst (ON Semiconductor), CAT812LEUS-T Datasheet - Page 6

no-image

CAT812LEUS-T

Manufacturer Part Number
CAT812LEUS-T
Description
Supervisory Circuits 4.63V Push-Pull High
Manufacturer
Catalyst (ON Semiconductor)
Datasheet

Specifications of CAT812LEUS-T

Product Category
Supervisory Circuits
Number Of Voltages Monitored
1
Monitored Voltage
2.5 V, 3 V, 3.3 V, 5 V
Undervoltage Threshold
4.56 V
Overvoltage Threshold
4.7 V
Output Type
Active High, Push-Pull
Manual Reset
Resettable
Watchdog
No Watchdog
Battery Backup Switching
No Backup
Power-up Reset Delay (typ)
240 ms
Supply Voltage - Max
5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
SOT-143-4
Chip Enable Signals
No
Maximum Power Dissipation
320 mW
Minimum Operating Temperature
- 40 C
Power Fail Detection
No
Factory Pack Quantity
3000
Supply Current (typ)
8 uA
Supply Voltage - Min
1.2 V
Reset Timing
threshold trip voltage and remains asserted for at least 140 ms after the power supply voltage has risen above the threshold.
V
Short duration transients of 4 ms or less and 100 mV
amplitude typically do not cause a false RESET.
negative−going V
condition. As the amplitude of the transient goes further
below the threshold (increasing V
pulse duration decreases. In this test, the V
initial voltage of 0.5 V above the threshold and drops below
it by the amplitude of the overdrive voltage (V
CC
The reset signal is asserted LOW for the CAT811 and HIGH for the CAT812 when the power supply voltage falls below the
The CAT811/812 protect mPs against brownout failure.
Figure 7 shows the maximum pulse duration of
30
25
20
15
10
5
0
Figure 7. Maximum Transient Duration without
Transient Response
Causing a Reset Pulse vs. Reset Comparator
1
CAT811
CAT812
RESET OVERDRIVE V
RESET
RESET
CAT8xxM
CC
V
CC
10
transients that do not cause a reset
Overdrive
V
5 V
0 V
5 V
0 V
0 V
CC
CAT8xxZ
TH
TH
− V
− V
100
CC
CC
(mV)
CC
T
), the maximum
AMB
Figure 6. Reset Timing Diagram
starts from an
DETAILED DESCRIPTION
TH
= 25°C
− V
http://onsemi.com
1000
CC
).
6
Valid Reset with V
when V
between RESET pin and GND is recommended; the value
is not critical. For the CAT812, a pull−up resistor from
RESET pin to V
To ensure that the CAT811 RESET pin is in a known state
Figure 8. RESET Valid with V
Figure 9. RESET Valid with V
CC
Threshold
Supply
Supply
Power
Voltage
Power
is under 1.0 V, a 100 kW pull−down resistor
CC
CC
is needed.
under 1.0 V
MR
MR
minimum
CAT811
CAT812
140 ms
GND
GND
V
V
RESET
CC
CC
RESET
Reset
Timeout Period
CC
CC
Under 1.0 V
Under 1.1 V
100 kW
100 kW

Related parts for CAT812LEUS-T