MAX44000EVSYS# Maxim Integrated, MAX44000EVSYS# Datasheet - Page 4

no-image

MAX44000EVSYS#

Manufacturer Part Number
MAX44000EVSYS#
Description
Optical Sensor Development Tools MAX44000 EVAL KIT
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX44000EVSYS#

Rohs
yes
Tool Is For Evaluation Of
MAX44000
Interface Type
I2C
Maximum Operating Temperature
+ 105 C
Description/function
Evaluation system
Minimum Operating Temperature
- 40 C
Operating Supply Current
7 uA
Operating Supply Voltage
1.7 V to 3.6 V
Product Type
Evaluation Module
• MAX44000 EV kit (USB cable included)
• Windows XP, Windows Vista, or Windows 7 PC with a
Note: In the following sections, software-related items are
identified by bolding. Text in bold refers to items directly
from the EV system software. Text in bold and underline
refers to items from the Windows operating system.
The EV kit is fully assembled and tested. Follow the steps
below to verify board operation:
1) Visit
2) Install the EV kit software and USB driver on your com-
3) Verify that all jumpers (JU6, JU7, JU8, and JU10–
4) Connect the USB cable from the PC to the EV kit
5) Start the EV kit software by opening its icon in the
6) On the Proximity Sensor Configuration tab sheet
7) Select ALS and Prox interleaved from the Operation
spare USB port
the latest version of the EV kit software, 44000Rxx.ZIP.
Save the EV kit software to a temporary folder and
uncompress the ZIP file.
puter by running the INSTALL.EXE program inside
the temporary folder. The program files are copied to
your PC and icons are created in the Windows Start
| Programs menu. During software installation, some
versions of Windows may show a warning message
indicating that this software is from an unknown pub-
lisher. This is not an error condition and it is safe to
proceed with installation. Administrator privileges are
required to install the USB device driver on Windows.
JU17) are in their default positions, as shown in
Table 1.
board. A Windows message appears when connect-
ing the EV kit board to the PC for the first time. Each
version of Windows has a slightly different message.
If you see a Windows message stating ready to use,
then proceed to the next step. Otherwise, open the
USB_Driver_Help_200.PDF document in the Windows
Start | Programs menu to verify that the USB driver
was installed successfully.
Start | Programs menu. The EV kit software main
window appears, as shown in Figure 1.
(Figure 2), in the Transmit Configuration group box,
use the LED Drive Current (DRV[3:0]) track bar to
set the IR LED current to 10mA. Press the adjacent
Set button.
Mode drop-down list.
www.maxim-ic.com/evkitsoftware
_________________________________________________________________ Maxim Integrated Products 4
Required Equipment
Quick Start
Procedure
to download
8) On the Data Conversion tab sheet (Figure 1),
The MAX44000 EV kit software (Figure 1) has all the
functions to configure the MAX44000 and receive the
ADC data from the device. The software contains an I2C
Interface group box, a Status group box, and four tab
sheets to configure the device and receive the ambient
and proximity data from the device.
In the I2C Interface group box, enter the register address
in the Reg Address edit box and press the Read button
to read the register. The returned value is shown in the
Data edit box. To write a data into a register, enter the
register address in the Reg Address edit box, enter the
data into the Data edit box, and press the Write button.
Use the Operating Mode drop-down list to select one
of the six operating modes. The operating modes are:
Shutdown, Standard ALS, ALS Green channel only,
ALS Red channel only, ALS and Prox interleaved, and
Prox only.
The Single Conversion group box on the Data
Conversion tab sheet displays the Ambient and
Proximity ADC values for a single sample. Press the
Convert button to update the values in the Ambient
and Proximity group boxes. Check the Auto Convert
checkbox to automatically and repeatedly do the ADC
conversion and update the values in the Ambient and
Proximity group boxes. Check the Save to File check-
box to save the received data to a file.
Press the Convert Start button in the Continuous
Conversion group box to continuously read the
ambient and proximity ADC data from the device and plot
the data on the Ambient Sensor and Proximity Sensor
graphs. The rate that the controller reads the data from
the device is selected from the Displaying Rate drop-
down list. The last ambient and proximity samples are
displayed in the Last ALS/PROX Reading group box in
the Status group box. Check the Save to File checkbox
to save the received data to a file.
The white LED (WLED) on the EV kit simulates the back-
light of a cell phone. The software adjusts the brightness
of the WLED according to the ambient measurement.
press the Convert Start button in the Continuous
Conversion group box to view the ambient and prox-
imity ADC data on the graphs.
Detailed Description of Software
Evaluates: MAX44000
Data Conversion Tab
Operating Mode
I
2
C Interface

Related parts for MAX44000EVSYS#