ZZ-PROG1-USB B&B Electronics (Quatech), ZZ-PROG1-USB Datasheet

no-image

ZZ-PROG1-USB

Manufacturer Part Number
ZZ-PROG1-USB
Description
RF Development Tools Zlinx Programming Cable
Manufacturer
B&B Electronics (Quatech)
Type
Wireless Trackingr
Datasheet

Specifications of ZZ-PROG1-USB

Rohs
yes
Product
Programming Kits
Tool Is For Evaluation Of
Zlink Wireless IO
Frequency
900 MHz, 2.4 GHz
Operating Supply Voltage
48 VDC
Interface Type
USB
Maximum Operating Temperature
+ 55 C
Minimum Operating Temperature
- 40 C
For Use With
Zlink Wireless IO
 Modular, Customizable Wire Replacement
 128 / 256 Bit AES Encryption
 Software Selectable RF Transmit Power
 Software Selectable Over-the-air Data Rate
 Modbus ASCII /RTU Compatible
 Wide Operating Temperature
 Active Repeater Functionality
 10 to 40 VDC & 24 VAC Input Power
Zlinx™ Wireless Modbus I/O - flexible enough to fit your
applications. These plug-n-play units from B&B Electronics
combine traditional Modbus RTU remote analog and discrete I/O
with built-in wireless connectivity. Wireless RTU serves as
Modbus slave RTU in radio-based SCADA systems, or as a
peer-to-peer communication platform.
Three Ranges Available - Short, Medium, Long range.
Active Repeaters - With built-in repeater functionality on -MR
and 900 MHz -LR models, you can ensure vital signals get
through.
Modular - Just snap on your I/O and you're ready to go.
Wide Temperature - Meets most indoor or outdoor applications.
Rugged circuitry prevents signal degradation.
128 / 256 Bit AES Encryption – Secures your data.
Selectable RF Transmit Power – Allows you to optimize the
transmitter power for your application.
Selectable Over-the-air Data Rate – Allows you to decrease the
OTA Data Rate on –LR and –LR-AU versions, effectively
increasing the radio transmitter’s range.
Exception Reporting – In Modbus mode, allows the reporting of
possible problems with connected devices.
Fail Safe – Allows you to set your I/O to a safe state in the event
of a communications failure.
Calibration – Calculates correction factors to make I/O values
better match your sensor.
Communications Failure Alarm – Allows the first DO to be
configured as a COM failure alarm indicator.
Invert Output – You can invert the logic of all DO’s in peer-to-
peer mode.
Monitor – You can use the Zlinx™ Manager Software to monitor
your I/O.
Peer-to-Peer and Modbus I/O
Zlinx Wireless I/O
European Office: Westlink Commercial Park Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445
International Office: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104
www.bb-elec.com orders@bb-elec.com
Replicate any analog or digital signal from a remote location-
Wirelessly! Use a pair of Zlinx™ Wireless I/O modules to read
sensor inputs or control actuators in hard-top-reach locations.
Inputs and outputs of the paired Zlinx radios will mirror each
other, making it easy to add wireless I/O to any application.
Seamlessly add wireless I/O to any Modbus application.
Modbus is the most widely supported I/O protocol worldwide.
With Zlinx Wireless I/O you can now bring wireless remote I/O
into any Modbus system. Simply connect a Zlinx modem to and
RS-232 or RS-485 port of the Modbus master and it can now
poll up to 150 wireless I/O nodes – each node can be
configured for 8 to 48 I/O points.
Modbus Peer-to-peer or Peer to Multi-peer
Wire Replacement (Peer-to-Peer Mode)
Zlinx Wireless Modbus I/O-0712ds page 1/5
©2009 B&B Electronics. All rights reserved
support@bb-elec.com

Related parts for ZZ-PROG1-USB

ZZ-PROG1-USB Summary of contents

Page 1

Zlinx Wireless I/O Peer-to-Peer and Modbus I/O  Modular, Customizable Wire Replacement  128 / 256 Bit AES Encryption  Software Selectable RF Transmit Power  Software Selectable Over-the-air Data Rate  Modbus ASCII /RTU Compatible  Wide Operating Temperature ...

Page 2

... Software Programming Kits – Required to program your system Model Number Programming Module (USB Interface), USB cable and Software CD ZZ-PROG1-USB Note: The Software CD is only available with the programming kit. Software and Firmware can also be downloaded at www.bb-elec.com Base Module Radio Properties ...

Page 3

... European Office: Westlink Commercial Park Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445 Zlinx Wireless Modbus I/O-0712ds page 3/5 ©2009 B&B Electronics. All rights reserved Analog Inputs and Outputs VDC ZZ-4AO active current source. All others are passive 12 Bit 0.2% full scale reading typical 0.27% full scale reading typical ...

Page 4

... ZZ9D-Nx-LR (900 MHz, Long range) ZZ-2AI2AO ZZ-4AI ZZ-4AO ZZ-4AO-2 ZZ-4DI4DO-DCT ZZ-4DI4DO-DCT1 ZZ-4RTD1 ZZ-8DI-DC ZZ-8DO-R ZZ-8DO-T ZZ-8DO-T1 ZZ-PROG1-USB Class 1, Div 2 exceptions: ZZ-8DO-R is not UL508 listed ZZxxD-Nx-MR, ZZxxD-Nx-xR-AU and ZZ8D-Nx-xR models are not Class 1, Div 2 listed but are UL508 listed MTBF(Hours) ZZ24D-NA-SR 85547 ZZ24D-NB-SR ZZ24D-NC-SR 86247 ...

Page 5

International Office: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104 European Office: Westlink Commercial Park Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445 Zlinx Wireless Modbus I/O-0712ds page 5/5 ©2009 ...

Related keywords