The MFR_NV_LOG_CONFIG command is used to
configure the operation of the nonvolatile fault logging
Table 25. MFR_NV_LOG_CONFIG
*The device clears two fault logs at a time when overwrite is enabled.
Maxim Integrated
PMBus 16-Channel Voltage Monitor and Sequencer
13:11
BIT
8:7
5:0
15
14
10
9
6
FORCE_NV_FAULT_LOG
CLEAR_NV_FAULT_LOG
NV_LOG_OVERWRITE
NV_LOG_T0_CONFIG
NV_LOG_DEPTH[1:0]
NV_LOG_FAULT
NAME
MFR_NV_LOG_CONFIG (D8h)
0
0
Setting this bit to a 1 forces the
set, the
for subsequent action. If an error occurs during this action, the device sets the CML
bit in STATUS_WORD; no bits are set in STATUS_CML.
Setting this bit to a 1 forces the
to all byte locations. Once set, the
The host must set again for subsequent action. If an error occurs during this action,
the device sets the CML bit in STATUS_WORD; no bits are set in STATUS_CML. While
clearing the fault log, monitoring is stopped and commands should not be sent to the
PMBus port.
These bits always return a 0.
This bit determines the source of the data written into the T0 location of each page
when a nonvolatile fault log is written.
0 = Log the last regular collection interval ADC reading.
1 = Read the latest ADC value before logging.
0 = Do not overwrite the NV fault log.
1 = Overwrite the NV fault log once it is full.*
These bits determine the depth of the NV fault log:
NV_LOG_DEPTH[1:0]
0 = Do not write NV fault log when FAULT is externally pulled low.
1 = Write NV fault log when FAULT is externally pulled low if the FAULT_IGNORE bit in
MFR_MODE is not set.
These bits always return a 0.
00
01
10
11
device
ADC RESULT COLLECTION NV FAULT LOG
clears this bit when the action is completed. The host must set again
in the device. The MFR_NV_LOG_CONFIG command is
described in
INTERVAL (ms)
device
device
device
160
20
80
5
MEANING
to clear the nonvolatile fault log by writing FFh
to log data into the nonvolatile fault log. Once
Table
clears this bit when the action is completed.
25.
DEPTH (ms)
MAX34461
100
400
800
25
46