M29W128GH70ZS6E NUMONYX, M29W128GH70ZS6E Datasheet - Page 43

no-image

M29W128GH70ZS6E

Manufacturer Part Number
M29W128GH70ZS6E
Description
IC FLASH 128MBIT 70NS 64FBGA
Manufacturer
NUMONYX
Series
Axcell™r
Datasheet

Specifications of M29W128GH70ZS6E

Format - Memory
FLASH
Memory Type
FLASH
Memory Size
128M (16Mx8, 8Mx16)
Speed
70ns
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
64-FBGA
Cell Type
NOR
Density
128Mb
Access Time (max)
70ns
Interface Type
Parallel
Boot Type
Not Required
Address Bus
24/23Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
FBGA
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
16M/8M
Supply Current
10mA
Mounting
Surface Mount
Pin Count
64
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W128GH70ZS6E
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
M29W128GH70ZS6E
Manufacturer:
ST
0
M29W128GH, M29W128GL
Command interface
Password Read command
The Password Read command is used to verify the password used in password protection
mode.
To verify the 64-bit password, the complete command sequence must be entered eight
times at eight consecutive addresses selected by A1-A0 plus DQ15A-1 in 8-bit mode, or
four times at four consecutive addresses selected by A1-A0 in 16-bit mode.
If the password mode lock bit is programmed and the user attempts to read the password,
the device will output FFh onto the I/O data bus.
An Exit Protection Command Set command must be issued to return the device to read
mode.
Password Unlock command
The Password Unlock command is used to clear the NVPB lock bit allowing to modify the
NVPBs.
The Password Unlock command must be issued along with the correct password.
There must be a 1 µs delay between successive password unlock commands in order to
prevent hackers from cracking the password by trying all possible 64-bit combinations. If
this delay is not respected, the latest command will be ignored.
Approximately 1 µs is required for unlocking the device after the valid 64-bit password has
been provided.
6.3.5
Non-volatile protection mode command set
Enter Non-volatile Protection Command Set command
Three bus write cycles are required to issue the Enter Non-volatile Protection Command Set
command. Once the command has been issued, the commands related to the non-volatile
protection mode can be issued to the device.
Non-volatile Protection Bit Program command (NVPB Program)
A block can be protected from program or erase by issuing a Non-volatile Protection Bit
command along with the block address. This command sets the NVPB to ‘1’ for a given
block.
The Non-volatile Bit Program command is a special kind of Program command and must be
used according to all the Program command timings. The result from this command can be
verified by checking the status register.
Read Non-volatile Protection Bit Status command (Read NVPB Status)
The status of a NVPB for a given block or group of blocks can be read by issuing a Read
Non-Volatile Modify Protection Bit command along with the block address.
Clear all Non-volatile Protection Bits command (Clear all NVPBs)
The NVPBs are erased simultaneously by issuing a Clear all Non-volatile Protection Bits
command. No specific block address is required. If the NVPB lock bit is set to ‘0’, the
command fails.
43/94

Related parts for M29W128GH70ZS6E